Page 141
Appendix B
Specifications
Transistor Output Unit C200H-OD214 (Load Short-circuit Protection Provided) Min. Switching Capacity
24 VDC +10%/–15% 0.8 A (2.4 A/Unit) surge current 2 A (source type) PNP output None
Leakage Current
1 mA max.
Residual Voltage
1.5 V max.
ON Response Time
1 ms max.
OFF Response Time
1 ms max.
No. of Circuits
1 (8 points/common)
Internal Current Consumption
140 mA 5 VDC max.
Fuse Rating
Short-circuit protection
Power for External Supply
150 mA 24 VDC +10%/–15% min.
Weight
250 g max.
Dimensions
A-shape
Max. Switching Capacity
Overcurrent protection Thermal protection
Circuit Configuration OUT L
Output indicator Source Driver Internal Circuit Reset
+V OUT L
+
24 VDC button COM Alarm Output indicator
Terminal Connections 0
L
1
L
2
L L
24 VDC (0.8 A max., 2.4 A/Unit)
L L L L
3 4 5 6 7
A0 A1 A2 A3 A4 A5 A6 A7
COM (OV)
A8
24 VDC
A9
Note Be sure to supply power to A9; otherwise current will leak through the load while the output is OFF.
134
Page 142
Appendix B
Specifications C200H-OD214 Short-Circuit Protection
The C200H-OD214 Output Unit is equipped with two types of short-circuit protection: overcurrent protection and thermal protection. Any short-circuit must be eliminated immediately in order to avoid damage to the Unit. Overcurrent Protection When the output current reaches 2 A, the alarm output turns ON, and the alarm indicator lights. Make sure the surge current of the load does not exceed 2 A, or the alarm may be activated. Thermal Protection When the junction temperature of the output transistor reaches its upper limit, the output turns OFF, the alarm output turns ON, and the alarm indicator blinks. But the output transistor is provided with a heat sink. So in some cases, when the output is short-circuited the thermal protection may not activate because the extra heat is dissipated by the heat sink. However, the alarm indicator will still light and the alarm output will still turn ON. How It Works When the short-circuit protection activates, the output displays the characteristic shown below. Output Voltage
Overcurrent limit alarm output point
Output current: 2 A (minimum value)
0
Each pair of outputs share one alarm indicator and one alarm output bit as shown below (bits 12 through 15 cannot be used as IR bits) Output No.
0
1
2
3
4
5 6
7
Alarm indicator No.
0
2
4
6
Alarm Output Point No.
08
09
10
11
Both the alarm indicator and alarm output bit for the short-circuited output turn ON even if only one of the outputs is short-circuited. Both outputs should be disconnected until the short-circuit can be traced. Clearing the Alarm When the short-circuit has been eliminated, reset the Unit by pressing the reset button. The alarm indicator will go out, the alarm output will turn OFF, and the output will be reset. Output indicator
Alarm indicator Reset button (use a screwdriver or other similar object to press it).
Programming Example If there is a short-circuit in an output, we want the program to turn that output OFF. Assume that the Unit is mounted at word 000. A program to turn OFF output bits 00 and 01 is shown below. A
00008 00000
B
00008 00001
Since alarm output bit 08 covers both output bits 00 and 01, both these outputs are forced OFF as soon as output bit 08 turns ON (bits A and B can be any other bits required in the program).
135
Page 143
Appendix B
Specifications
Transistor Output Unit C200H-OD216 Max. Switching Capacity
0.3 A 5 to 24 VDC
Min. Switching Capacity
10 mA 5 VDC
Leakage Current
0.1 mA max.
Residual Voltage
1.5 V max.
ON Response Time
1.5 ms max.
OFF Response Time
2 ms max.
No. of Circuits
Fuse Rating
1 (8 points/common) positive common (source type) 10 mA 5 VDC max. 75 mA 26 VDC (8 points ON simultaneously.) None
Power for External Supply
N/A
Weight
250 g max.
Dimensions
A-shape
Internal Current Consumption
Circuit Configuration
OUT
L
Output indicator OUT
L
Internal Circuit
5 to 24 VDC COM
Terminal Connections L L L L
5 to 24 VDC
L L L L
0 1 2 3 4 5 6 7
A0 A1 A2 A3 A4 A5 A6 A7
COM A8 NC A9
136
Page 144
Appendix B
Specifications
Transistor Output Unit C200H-OD217 Max. Switching Capacity
0.3 A 5 to 24 VDC
Min. Switching Capacity
10 mA 5 VDC
Leakage Current
0.1 mA max.
Residual Voltage
1.5 V max.
ON Response Time
1.5 ms max.
OFF Response Time
2 ms max.
No. of Circuits
Fuse Rating
1 (12 points/common) positive common (source type) 10 mA 5 VDC max. 75 mA 26 VDC (8 points ON simultaneously.) None
Power for External Supply
N/A
Weight
300 g max.
Dimensions
B-shape
Internal Current Consumption
Circuit Configuration
OUT L
Output indicator OUT L
Internal Circuit
5 to 24 VDC COM
Terminal Connections
L L
5 to 24 VDC
L L L L
1 3 5 7 9 11
A0 A1 A2 A3 A4 A5
NC A6 NC A7 COM A8
B0
0
B1
2
B2
4
B3
6
B4
8
B5 10
L L L L L L
B6 NC B7 NC B8 NC B9 NC
137
Page 145
Appendix B
Specifications
Transistor Output Unit C200H-OD411 Max. Switching Capacity
12 to 48 VDC 1 A (3 A/Unit)
Min. Switching Capacity
None
Leakage Current
0.1 mA max.
Residual Voltage
1.4 V max.
ON Response Time
0.2 ms max.
OFF Response Time
0.3 ms max.
No. of Circuits
1 (8 points/common)
Internal Current Consumption
140 mA 5 VDC max.
Fuse Rating
5 A 125 V (5.2-dia.x20)
Power for External Supply
30 mA 12 to 48 VDC min.
Weight
250 g max.
Dimensions
A-shape
Circuit Configuration OUT
L
V Output indicator OUT L Internal Circuit
Fuse
COM 12 to 48 VDC
Fuse blowout detection circuit
Fuse: GSS (Nagasawa) 5 A 125 V 5.2-dia 20
F indicator
Note When the fuse blows, the F indicator lights and bit 08 turns ON. Bits 08 through 15 cannot be used as IR bits. Terminal Connections L L L L
12 to 48 VDC (1 A max., 3 A/Unit)
L L L L
0 1 2 3 4 5 6 7
A0 A1 A2 A3 A4 A5 A6 A7
COM (OV)
A8
12 to 48 VDC
A9
Note Be sure to supply power to A9; otherwise current will leak through the load while the output is OFF.
138
Page 146
Appendix B
Specifications
Transistor Output Unit C200H-OD21A (Load Circuit Protection Provided)
Min. Switching Capacity
24 VDC +10%/–15%, 1.0 A (4 A/Unit) surge current 1.6 A (sourcing type) PNP output None
Leakage Current
0.1 mA max.
Residual Voltage
0.8 V max.
ON Response Time
0.1 ms max.
OFF Response Time
0.3 ms max.
No. of Circuits
1 (16 points/common)
Internal Current Consumption
160 mA 5 VDC max.
Power for External Supply
35 mA 24 VDC +10%/–15% min.
Weight
400 g max.
Alarm Output (see note 1)
No. of outputs: 1 (2 kΩ internal resistor) Connectable Units: Only the following DC Input Units and alarm output LED indicators can be connected: C200H-ID001, ID211, ID212, IM211 (DC), IM212 (DC), ID215, ID501, MD115, MD215, MD501
Reset Input
Used when alarm output turns ON. Value will depend on the external power supply. (See note 2.) Detection current: 1.2 A min. (1.6 A typical) B-shape
Max. Switching Capacity
Load Short-circuit Protection Dimensions
Internal Circuit
Output LED indicator
Short-circuit protection circuit
Circuit Configuration to 0V 2 kΩ
Note 1. When the short-circuit/overload protection is activated, all 16 outputs are switched OFF and the ALARM output becomes active (low level). It is possible to determine the cause of the alarm by connecting either a DC Input Unit to the alarm output or an alarm output LED indicator. 2. When alarm output turns ON, remove the cause of the overload, turn OFF the external power supply (for about 1 s), and confirm that the error has been cleared before turning ON power again and restoring output. As indicated in the following terminal connections diagram, it is recommended that a relay or switch used solely to turn ON and OFF the Unit’s external power supply be connected immediately in front of B9 (+V). In this case, use a relay or switch with a contact capacity that is greater than the current consumption of the external power supply for the Unit (35mA) + the load current.
139
Page 147
Appendix B
Specifications Terminal Connections +24 VDC
24 VDC
C200HS-INT01 Interrupt Input Unit The Interrupt Input Unit temporarily interrupts the main program by means of inputs, and executes interrupt subroutines. It must be mounted to a C200HS CPU Rack, and there can be only one Interrupt Input Unit on the Rack. (It is possible to mount it to an Expansion I/O Rack, but in that case it will be treated as a Standard Input Unit and will have no interrupt functions.) Use a C200H-BCjj1-V2 Backplane. The word number of the slot position to which the Unit is mounted is allocated as eight input points.
Operation display area: Displays the ON/OFF status of interrupts.
Terminal block: Consists of removable components.
140
Rated Input Voltage
12 to 24 VDC +10%/–15%
Input Impedance
2 KΩ
Input Current
10 mA typical (24 VDC)
ON Voltage
10.2 VDC min.
OFF Voltage
3.0 VDC max.
ON Response Time
0.2 ms max.
OFF Response Time
0.5 ms max.
No. of Circuits
1 (8 points/common)
Internal Current Consumption
20 mA, 5 VDC max.
Weight
200 g max.
Page 148
Appendix B
Specifications Circuit Configuration IN
IN
2 kW
COM
0.01 mF
Internal Circuit
1.8 kW
12 to 24 VDC
Input indicator
Either plus or minus can be used for the input power supply.
Terminal Connections 0 1 2 3 12 to 24 VDC
4 5 6 7 COM
NC
A0 A1 A2 A3 A4 A5 A6 A7 A8 A9
Group-2 High-density I/O Units In the following diagrams, “m” is the first word allocated to the Unit in PC memory.
DC Input Unit C200H-ID111 (64 Points) Rated Input Voltage
12 VDC +10%/–15%
Operating Input Voltage
10.2 to 13.2 VDC
Input Impedance
2.7 kW
Input Current
4.1 mA (at 12 VDC)
ON Voltage
8.0 VDC min.
OFF Voltage
3.0 VDC max.
ON Response Time
1.0 ms max.
OFF Response Time
1.0 ms max.
No. of Circuits
2 (32 points/common)
Internal Current Consumption
120 mA 5 VDC max.
Weight
250 g max.
Dimensions
D-shape
141
Page 149
Appendix B
Specifications Circuit Configuration COM 1000 pF Internal Circuit
IN00 A
IN07 COM IN08
CN1
820 W 2.7 kW CN1
IN15 COM IN00
Input indicator
IN15 COM IN00
1000 pF
IN07 COM IN08
A
Indicator switch circuit
CN2
IN07 COM IN08
B
SW
Internal Circuit
820 W 2.7 kW
IN15 COM IN00
CN2
IN07 COM IN08
B
IN15
Terminal Connections CN1 I/O word “m+1” NC NC COM
15 12 VDC
+
A
20
20
19
19
18
18
17
I/O word “m+2” 0
NC
1
NC
2
COM
17
15
4
16
16
13
15
15
13
12 VDC
14
14
12
+
13
11
12
13
10
12
12
10
9
11
11
9
8
10
10
8
7
9
9
8
8
7
6
6
5
12 VDC
5
5
4
+
3
4
4
3
2
3
3
2
1
2
2
1
1
0
1
3
3
4
4
1 2 3
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
NC
19
19
NC
NC
20
20
NC
13 14 15 COM
5
+
6 7 COM
8 9 10 11
12 VDC
12 13 14 15 COM
Note 1. I/O word “m” is determined by the I/O number setting (m = IR 030 + 2 × I/O number).
142
12 VDC
4
8
11
+
2
7
12
5
2
0
7
9
7
1
6
10
7
1
5
8
12 VDC
B
6
COM
COM
I/O word “m+3” A
5
5
7
6
0
+
6
6
4
3
12 VDC
14
COM
+
I/O word “m” B
14
11
12 VDC
CN2
+
Page 150
Appendix B
Specifications
2. The power can be supplied in either polarity, but the same polarity must be used for all COM terminals in each connector. Connect power supply wiring to every COM terminal, even though the COM terminals in each connector are connected internally.
DC Input Unit C200H-ID216 (32 Points) Rated Input Voltage
24 VDC
Operating Input Voltage
20.4 to 26.4 VDC
Input Impedance
5.6 kW
Input Current
4.1 mA (at 24 VDC)
ON Voltage
14.4 VDC min.
OFF Voltage
5.0 VDC max.
ON Response Time
1.0 ms max.
OFF Response Time
1.0 ms max.
No. of Circuits
1 (32 points/common)
Internal Current Consumption
All 32 points cannot be turned ON simultaneously at high temperatures. Refer to the following graph. 100 mA 5 VDC max.
Weight
180 g max.
Dimensions
C-shape
Circuit Configuration and Simultaneously Usable Points 32 30
COM
Input Voltage: 26.4 VDC
1000 pF IN00 IN07 COM IN08
25
680 W 5.6 kW Input indicator
IN15
Internal Circuit COM 1000 pF IN00 B
IN07 COM IN08
680 W
20 15 10 5
5.6 kW Input indicator
IN15
Simultaneously Usable Points
A
0 0
10
20
30
40
50 55 60
Ambient Temperature (°C)
143