Page 41

Bulletin: 30598-257-02A1

Addendum Subject:

1 of 2

Date:

October 16, 1997

Class 8030 Type EQ5166 Network Interface Module for Toledo® Scale Corporation Model 8142 Digital Scale Indicator (Addendum for Instruction Bulletin 30598-257)

DESCRIPTION The EQ5166 network interface module (NIM) has been designed to permit acquisition of weight and related data via the SY/NET network from a Toledo Scale Corporation Model 8142 Digital Scale Indicator. The Type EQ5166 Toledo Scale Corporation Network Interface Module (TSC-NIM) can use both the COMM Port 0 and COMM Port 1 to communicate with up to two (2) Model 8142 digital scale indicators. The TSC-NIM is based on the existing SY/NET Class 8030 CRM510 NIM. The CRM510 firmware has been altered to recognize the character streams unique to the Model 8142 JN Port Toledo Continuous Format. This format is defined in the Peripheral Mode (refer to DIP switch settings and special cable requirements on page 2). In this mode, the data acquired from the two COMM ports is only character data. The predefined format identifies the start and end of each message block into a response buffer which will be sent back over SY/NET to the requesting device(s). If another message block begins while the TSC-NIM is processing one, the new message block is appended to the input buffer to prevent losing it. When the response is completed, the TSC-NIM verifies the computed checksum value using the checksum sent from the Model 8142. If the checksum is correct, the response is sent to the requesting device. If not, an error code of decimal 33 (Hex 21) is sent to the requesting device. The error code 33 would indicate a File Data Detected which describes the block of data involved in the READ operation was faulty. This is usually detected through the TSC-NIM during comparisons of checksum. DATA FORMAT The data sent in the response packet will consist of sixteen (16) contiguous registers. Each seven (7) bit value acquired from the Model 8142 will be right justified in the sixteen (16) bit SY/MAX® register. The first three (3) registers will contain binary status information. The next six (6) registers will contain the ASCII code for the six (6) decimal digits of the displayed weight data. The next six (6) registers will contain the ASCII code for the six (6) decimal

Copyright © 1992 Square D Company

Page:

digits of the tare weight data. The last register will have the ASCII code for a carriage return (Decimal value - 13, Hexadecimal value - 0D). REGISTER NO.

DATA

FORMAT

1

Status

Binary

2

Status

Binary

3

Status

Binary

4

Weight

ASCII

5

Weight

ASCII

6

Weight

ASCII

7

Weight

ASCII

8

Weight

ASCII

9

Weight

ASCII

10

Tare

ASCII

11

Tare

ASCII

12

Tare

ASCII

13

Tare

ASCII

14

Tare

ASCII

15

Tare

ASCII

16

CR

ASCII

PORT CONFIGURATIONS - TOLEDO SCALE The Toledo Scale Model 8142 JN port configuration must be as follows: Output Mode - Toledo Continuous Mode RS-422 Input Selection = RS-422 Baud Rate = 2400 Checksum = Enabled Minimum Print Increment = 0 ASCII Remote Command Input = Disabled Print Interlock / Autoprint = Disabled

Page 42

Page 2 of 2

30598-257-02A1

SY/NET NIM The TSC-NIM COMM port switch settings must be set in the following configuration for both ports: 8 data bits No parity Peripheral mode 2400 Baud rate NIM SWITCH SETTINGS Switch 3

Switch 4

Switch 5

1 2 3 4

1 2 3 4 5 6 7

1 2 3 4 5 6 7

Note - Please refer to the Type 8030 CRM510 Instruction Bulletin 30598-257 for a full description of the switch settings, physical locations and other general information. CABLE REQUIREMENT A cable must be prepared to permit communications between the Model 8142 JN port and the COMM 0 or COMM 1 port of the TSC-NIM. The recommended cable type is Belden 9535 or equal. The Model 8142 JN port requires a male 25 pin miniature D connector (A) and the COMM port of the TSC-NIM uses a male 9 pin subminiature D connector (B). The wire connections are as shown below: JN PORT TO NIM PORT CABLE Conn. A 8142 JN Port 11 12

Conn. B COMM 0 or 1 Port 1 2 3 4 5 6 7 8 9

Page 43 read from a scan by OCR; it may hold reading errors

;

> Indicator Lights

Thumbwheels

COMM Ports

Figure 2.3, Module Overview

NETWORK INTERFACE NUMBER

Figure 2.7 - Thumbwheel Switches

Figure 2.4 - Network Connector

@ NETWORK @ «xe

@

@ er @:

e NET Rs ERROR @ rev ERRoF (=) POWER

Figure 2.6 - NIM LEDs

Page 44 read from a scan by OCR; it may hold reading errors

Figure 2.5 - Side View, Cover Removed

Figure 2.8 - Printed Circuit Board Mounted Switches, _ - - - - _ - DEVICE

| NETWORK | NUMBER |

PRESENT ROUTE WOE ENTER DESIRED ROUTE

MODE: ROUTE Ss ee ee eee ee