Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Class 8030 Type CRM-510 Network Interface Module

Manual · Square D

Class 8030 Type CRM-510 Network Interface Module

Manual44 pagesPDF 1.3 MB

Instruction bulletin for the Square D Class 8030 Type CRM-510 SY/NET Network Interface Module used with SY/MAX programmable controllers.

Download the PDF1.3 MB

Covers · 2 models

The models it covers

Summary

What is in it

The instruction bulletin for the CRM-510 Network Interface Module (NIM), which links SY/MAX family programmable controllers, CRT programmers, printers, computers and other devices on a SY/NET network. It gives network and module specifications, installation and keying, indicator lights and switch settings, COMM port and network cabling, module operation and routing, the SY/MAX, Net to Net, Peripheral and 8881 modes, communication rung programming, troubleshooting and network performance.

Its parts

  1. Description
  2. Installation and Hardware
  3. Cabling - Wiring
  4. Module Operation
  5. Defining the Network
  6. Modes of Operation
  7. Application Programming
  8. Troubleshooting
  9. Advanced Capabilities
  10. Network Performance Considerations
  11. Appendices
  12. Addendum

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Square D instruction bulletin 30598-257-02 (January 1988) for the Class 8030 Type CRM-510 Network Interface Module, which lets SY/MAX controllers, computers, printers and other devices talk to each other over a SY/NET network. It covers mounting, switch settings, port and network cabling, operating modes, communication error codes and troubleshooting.

Read for this summary: pages 1, 4 to 12, 30 to 31 and 39 of 44.

Device
Network Interface Module (NIM) that links SY/MAX family devices over a SY/NET network p. 1, 5
Ports
Two independent RS-422 COMM ports, baud switch-selectable up to 9600; one SY/NET network port p. 5
Power
950 mA at 5 VDC through the rack backplane p. 5
Network size
Two devices per NIM; up to 100 NIMs and 200 devices per network p. 5
Mounting
Register slot of an I/O rack or any slot of a register rack, including CRK-100, CRK-200, CRK-210, CRK-300, DRK-210, DRK-300, GRK-110, GRK-210, HRK-200, RRK-100 and RRK-200 p. 5
Operating modes
Each COMM port: SY/MAX Family, Net to Net, 8881 or Peripheral mode, set by DIP switches p. 5, 9
Network cable
Belden 9463 or equivalent twinax cable; a 78 ohm terminator at each end p. 11, 12
Network length
62.5 K baud 15,000 ft; 125 K baud 9,250 ft; 250 K baud 4,250 ft; 500 K baud 2,400 ft (drop length 0) p. 12
Network parts
Cable end CCK-211, tee CCK-212, terminator set CCK-213, cable extension CCK-214; cables CC-201 (2 ft) and CC-202 (10 ft) p. 11
COMM cables
Class 8010 CC-100 (10 ft), CC-101 (30 ft), CC-102 (2 ft); kit CCK-102 for longer cables p. 10
RS-232 devices
Class 8010 Type CRM-600 RS-422 to RS-232 adapter with a CC-130 cable p. 10, 11
Factory settings
SY/MAX Family mode; ports 0 and 1 at 9600 baud; network port 62.5K baud; self test off p. 10
Network address
Set with two thumbwheel switches on the front of the module p. 7
Network method
Manchester encoded HDLC, token passing, CRC on all network transmissions p. 5

What this manual walks you through

  • Keying a register slot for the network module p. 5, 6
  • Setting the network baud rate, port baud rates and modes with the rear switches p. 8, 9, 10
  • Reading the eight indicator lights p. 7, 30
  • COMM port pinout and cables to SY/MAX and RS-232 devices p. 10, 11
  • Building the network cable with ends, tees and terminators p. 11, 12
  • Checking COMM port communication by the Rx and Tx lights p. 30, 31
  • Looking up communication error codes p. 31, 39
  • Running the module self-test p. 31

Good to know

  • Never remove the module from the rack while power is on. p. 4
  • Do not handle the module by the gold edge contacts; it is easily damaged by static. p. 4
  • The COMM ports are RS-422 and do not support RS-232C devices directly. p. 10
  • Set only one network baud switch up; otherwise the fastest rate is used. p. 8
  • The COMM ports supply no power, so a loader/monitor needs its own power supply. p. 11

Questions this manual answers

How many devices can a SY/NET network of CRM-510 modules have?

Each NIM supports two devices, and up to 100 NIMs fit on one network, so up to 200 devices. p. 5

What do the CRM-510 self-test error flashes mean?

With NET Rx and Tx flashing together: one flash is a ROM checksum error, two a RAM error, three a serial port 0 or 1 error, four a network port error. p. 31

What does communication error 17 mean on a CRM-510?

The remote device is inactive. The network interface module generates this code; check the cable connections between devices. p. 39

What cable connects a CRM-510 to a SY/MAX processor?

A Class 8010 CC-100 series cable: CC-100 (10 ft), CC-101 (30 ft) or CC-102 (2 ft); kit CCK-102 for runs over 30 feet. p. 10

What is the maximum SY/NET network cable length?

15,000 feet at 62.5 K baud, down to 2,400 feet at 500 K baud, with the tee connected directly to the module. p. 12

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Class 8030 Type CRM5101
  2. Network Interface Module1
  3. Description1
  4. Warnings and Cautions4
  5. 1: Description5
    1. 1.1 Introduction5
    2. 1.2 Specifications5
  6. 2: Installation and Hardware5
    1. 2.1 Installation5
    2. 2.2 Hardware6
  7. 3: Cabling - Wiring10
    1. 3.1 COMM Port10
    2. 3.2 Network Port11
  8. 4: Module Operation13
    1. 4.1 Power Cycling13
    2. 4.2 Message Handling13
    3. 4.3 Error Handling15
  9. 5: Defining the Network15
    1. 5.1 Routing15
    2. 5.2 Determining Network Device Number15
    3. 5.3 How to Use Routing15
    4. 5.4 Net-to-Net Routing16
  10. 6: Modes of Operation17
    1. 6.1 SY/MAX-Family Mode17
    2. 6.2 Net to Net Mode21
    3. 6.3 Peripheral Mode23
    4. 6.4 8881 Mode24
  11. 7: Application Programming27
    1. 7.1 Communication Rung Operation27
    2. 7.2 Communication Rung Examples28
  12. 8: Troubleshooting30
    1. 8.1 Module Troubleshooting30
    2. 8.2 System Troubleshooting31
  13. 9: Advanced Capabilities33
    1. 9.1 Special Route Values33
    2. 9.2 Route 233 - 254 Broadcast34
  14. 10: Network Performance Considerations35
    1. 10.1 Network Baud Rate35
    2. 10.2 100/30 Switch-Switch 7 on Switch Group S535
11 more lines, from page 36 on
  1. Appendices36
    1. A: Introduction to Networks36
    2. B: Installing a Network Cable End38
    3. C: Comm Error Codes39
    4. D: Summary of Switch Settings40
  2. Addendum41
    1. Description41
    2. Data Format41
    3. Port Config. - Toledo Scale41
    4. SY/NET NIM42
    5. Cable Requirement42

From the PDF’s own bookmarks.

The whole text · 10 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 31-3
  2. Pages 4 to 94-9
  3. 3: Cabling - Wiring10-12
  4. Pages 13 to 1613-16
  5. 6: Modes of Operation17-26
  6. 7: Application Programming27-29
  7. 8: Troubleshooting30-32
  8. Pages 33 to 3533-35
  9. Appendices36-40
  10. Addendum41-44

The file

Revision and size

RevisionInstruction Bulletin 30598-257-02, January 1988 (minor corrections 4/89)
PublisherSquare D Company
Pages44
PDF1.3 MB
TextThe pages are scans; their text was read by OCR, which may hold reading errors.

The first pages · 3 of 44

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 44
Page 2
Page 2of 44
Page 3
Page 3of 44