Manual · Schneider
RM14K Installation and Programming Manual
Manual164 pagesPDF 600 KB
Installation and programming manual for the Niobrara RM14K SY/MAX industrial modem for Square D Class 8030 register racks.
What this file really is
The old site listed this file as “Tech manual” for the Schneider 8030 CRM-510 and Square D 8030 CRM-510. Linked as the tech manual for the 8030 CRM-510, but it is the manual for the Niobrara RM14K Industrial Modem, which names the CRM-510 only as a device it can connect to.
Filed with · 2 models
Also filed with these models on the old site
Summary
What is in it
Manual for the Niobrara RM14K Industrial Modem, a SY/MAX compatible modem that mounts in a Square D Class 8030 register rack. It covers specifications, installation, dial-up, leased-line and radio operation, command and status bits, password security, the RM14KSW configuration software, many dial-up, leased-line and multidrop examples (including links to CRM-510 NIMs and PowerLogic circuit monitors), connector pinouts, cabling and troubleshooting.
Its parts
- Introduction
- Installation
- Operation
- Configuration Software RM14KSW
- Dial-up 11 Bit SY/MAX Examples
- Dial-up 10 Bit SY/MAX Examples
- Dial-up Transparent Examples
- Leased Line SY/MAX Examples
- Leased Line Transparent P-T-P Examples
- Multidrop Examples
- Connector Pinouts
- Recommended Cabling
- Troubleshooting
From the manual
Key facts from this manual
Each line names its page in the PDF.
Niobrara installation and programming manual (effective 31 July 2001) for the RM14K Industrial Modem, a SY/MAX compatible modem that mounts in a Square D register rack; it is filed here because it shows how to dial a remote SY/NET network through a CRM-510 Network Interface Module. It covers mounting, the RM14KSW software, phone line and leased line hookups, the control registers and troubleshooting.
- Device
- Niobrara RM14K Industrial Modem, SY/MAX compatible, for a register rack; RS-422 version RM14K-D p. 13
- Mounting
- One register slot of a Square D Class 8030 Type CRK, DRK, GRK, HRK or RRK rack, or an NR&D NRK1 or NRK2 p. 14
- Line types
- Dial-up phone lines (PSTN), 2- and 4-wire dry leased lines, and radios; up to 14.4K baud p. 13
- Operating modes
- SY/MAX mode and Transparent (Hayes) mode p. 13
- Serial port
- Female 9-pin D RS-422/485 port, active RTS/CTS handshake, SY/MAX pinout p. 14, 16
- Power
- 800 mA from the SY/MAX power supply; needs 4.75 VDC to run without resetting p. 14, 128
- Line connectors
- RJ11 jacks: PHONE, PSTN, LL TX and LL RX; the LL pair doubles as radio audio out and in p. 16
- Cables
- To a PC: Niobrara SC902 (or SC406) smart cable with external power supply; to a processor or NIM: CC-100 or DC1 p. 18, 71
- Modulation
- Full duplex Bell 103 300 bps up to V.32 bis 14400 bps; half duplex V.26 bis up to V.17 14,400 bps p. 15
- Dial input, PTT
- Dial input: optically isolated, 12 to 120 V AC or DC; PTT output: normally open reed relay, 1 Amp non-inductive, 150 V p. 14, 16
- Size and weight
- Single width module, 1.5 in. W, 12.8 in. H, 6.6 in. D, 2.5 lb. p. 14
- Temperature
- 0 to 60 degrees C operating, -40 to 80 degrees C storage; humidity up to 90% noncondensing p. 14
- Factory defaults
- RS-422 port 9600 baud, modem port 14400 baud; both EVEN parity, 8 data bits, 1 stop bit, BCC p. 18
- Software
- RM14KSW for MS-DOS, with DIAL, HANGUP, NRDMODE, NRDTERM and ZAPREG utilities p. 18
What this manual walks you through
- Installing the RM14K in a register rack p. 17
- Installing RM14KSW and going online from a PC p. 18, 19, 20
- Connecting to a dial-up phone line p. 21
- Wiring four-wire and two-wire leased line links p. 22
- Automatic redialing through chained phone number blocks p. 32
- Reading the error register R[6] p. 32
- Rack addressing the modem from the PLC p. 32
- Dialing a remote SY/NET network through a CRM-510 NIM p. 71, 72
- Troubleshooting from the front panel lights and by going online p. 127, 128
Good to know
- Do not install or remove the RM14K with power on the rack. p. 17
- Consult the factory before adjusting the transmit level. p. 15
- Registers above R[64] can only be reached from the modem port or data port, not from the PLC. p. 32
- When dialing in through a SY/LINK card, the NIM port may only be set for 9600 baud. p. 72
- Option bit 4 disables the front panel switches, so none of them may respond if it is set. p. 128
Questions this manual answers
What rack does the RM14K modem mount in?
One register slot of a Square D Class 8030 Type CRK, DRK, GRK, HRK or RRK rack, or an NR&D NRK1 or NRK2 rack assembly. p. 14
How is the RM14K connected to a CRM-510 NIM?
By a CC-100 or DC1 cable, as for a processor. The RM14K RS-422 port must match the NIM port, most likely 9600 baud, 8 data bits, EVEN parity, 1 stop bit, BCC. p. 71
What do the RM14K error register bits mean?
R[6] reads 0 with no errors; bits 1 to 8 flag illegal baud, parity or dial string settings, conflicting mode choices, or a port and line baud mismatch in Transparent mode. p. 32
Why do the RM14K lights keep strobing at power-up?
Check the rack power supply: the RM14K needs 4.75 VDC to run without resetting, and rack power should be right at 5.0 VDC. p. 128
What are the RM14K default serial port settings?
The SY/MAX serial port defaults to 9600 baud, EVEN parity, 8 data bits, 1 stop bit and BCC checksum. p. 127
The whole text · 17 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 81-8
- Pages 9 to 189-18
- Pages 19 to 2819-28
- Pages 29 to 3829-38
- Pages 39 to 4839-48
- Pages 49 to 5849-58
- Pages 59 to 6859-68
- Pages 69 to 7869-78
- Pages 79 to 8879-88
- Pages 89 to 9889-98
- Pages 99 to 10899-108
- Pages 109 to 118109-118
- Pages 119 to 128119-128
- Pages 129 to 138129-138
- Pages 139 to 148139-148
- Pages 149 to 158149-158
- Pages 159 to 164159-164
The file