SERI Installation and Programming Manual

Manual65 pagesPDF 442 KB

Installation and programming manual for the Niobrara SERI SY/MAX Ethernet Rack Master, with register maps for SY/MAX I/O such as the RIM-126.

What this file really is

The old site listed this file as “Tech Manual” for the Schneider 8030-RIM-126 and Square D 8030-RIM-126. This is the Niobrara SERI Ethernet rack master manual, not a Square D manual for the 8030-RIM-126; the RIM-126 appears only as one of the I/O modules it supports, with a register map.

Download the PDF442 KB

Filed with · 2 models

Also filed with these models on the old site

Summary

What is in it

Manual for the Niobrara SERI, a SY/MAX compatible Ethernet module that replaces the SY/MAX CPU or Remote Interface in slot 1 of a Square D Class 8030 rack so another PLC or SCADA can control the I/O over Modbus/TCP. It covers specifications, installation and firmware upgrades, the data mapper, the built-in web server, the SERISW32 configuration software, setup examples, pinouts and cabling, and register maps for SY/MAX I/O modules, including the 8030 RIM-126 analog input module.

Its parts

  1. 1 Introduction
  2. 2 Installation
  3. 3 Operation
  4. 4 Web Server
  5. 5 Configuration Software SERISW32
  6. 6 Setup Examples
  7. 7 Connector Pinouts
  8. 8 Recommended Cabling
  9. 9 Sy/Max Module Hardware Description

From the manual

Key facts from this manual

Each line names its page in the PDF.

Niobrara Research & Development's 2008 installation and programming manual for the SERI SY/MAX Ethernet Rack Master, a module that takes the CPU or remote interface slot of a Square D Class 8030 rack so a Modbus/TCP client can control the SY/MAX I/O. The site files it under the 8030-RIM-126, which the manual lists as a compatible module and describes on one page with its register map. It covers installation, the data mapper, configuration, cabling and firmware upgrades.

Read for this summary: pages 1 to 9, 11 to 13, 17 to 19, 49, 51 and 56 of 65.

RIM-126
RIM-126: 8 channel isolated analog input module for high level analog and low level thermocouple signals p. 56
RIM-126 registers
RIM-126: words 1-8 analog inputs; 9 open input bits; 10 under- and over-range bits; 11-12 DIP switch settings p. 56
SERI
SY/MAX compatible Ethernet module letting another PLC or SCADA control SY/MAX I/O over Modbus/TCP p. 7
Mounting
Register slot 1 (CPU slot) of a Class 8030 RRK-100, RRK200, RRK-300, HRK-100, HRK-150 or HRK-200 rack p. 8
Compatible modules
Discrete: HIM-101, HOM-221, RIM-101, RIM-331, RIM-731, ROM-221, ROM-271, RDO-732; intelligent: RIM-121, RIM-125, RIM-126, RIM-131, RIM-144, ROM-121, ROM-122, ROM-141, RAO-208 p. 8
Ethernet port
10BaseT RJ45, Modbus/TCP p. 7, 8
Serial port
9 pin female D-connector, RS-422; fixed 9600 baud, 8 data bits, 1 stop bit, EVEN parity; Modbus RTU and SY/MAX p. 8
Current draw
1100 mA from the SY/MAX power supply p. 8
Environment
0 to 60 degrees C operating, -40 to 80 storage; up to 90% humidity noncondensing p. 8
Size and weight
Single width; 2.5 lb; 1.5 in wide, 12.8 in high, 6.6 in deep p. 8
Data mapper
Up to 50 entries mapping I/O to Modbus holding registers 1-10000; slots 1-16 register, 17-32 digital p. 17
Network defaults
IP address 10.10.10.10, subnet mask 255.0.0.0, BOOTP/DHCP off p. 11, 12
Configuration
Built-in web server or included SERISW32 PC software; stored in Flash p. 7
Programming cable
Niobrara SC902 RS-232 to RS-422 cable, powered by +5VDC on pins 5 and 6 of the SERI port p. 12, 51

What this manual walks you through

  • Installing the SERI in the rack CPU slot p. 11
  • Connecting to the SERI at its default IP address p. 12
  • Upgrading the firmware over the RS-422 port p. 12, 13
  • Setting up the data mapper entries p. 17, 18, 19
  • Reading status, slot and default output registers p. 17, 18
  • Front panel lights and keyswitch p. 9
  • RS-422 COMM port pinout p. 49
  • RIM-126 register map and status bits p. 56

Good to know

  • Install or remove the SERI only with rack power off; SY/MAX racks are not hot swappable. p. 11
  • The Modbus/TCP client must write within the watchdog timeout, or outputs revert to their default values. p. 17
  • Only a client whose IP address is in the four-entry allowed master table may control the system. p. 7
  • Writing the control register continuously may greatly increase the SERI's scan time. p. 19

Questions this manual answers

Does the Niobrara SERI work with the Square D RIM-126?

Yes. The manual lists the RIM-126 among compatible intelligent modules and gives its register map. p. 8, 56

What is the default IP address of the SERI?

10.10.10.10 with subnet mask 255.0.0.0; set the PC to a similar address such as 10.10.10.11 and browse to 10.10.10.10. p. 12

How do I upgrade SERI firmware?

With the rack off, set the Load/Normal switch to LOAD, reinstall, connect the PC to the COMM port (an SC902 cable) and run FWLOAD; then set the switch back to NORMAL. p. 12, 13

What happens to SERI outputs if the Modbus master stops writing?

After the watchdog timeout the outputs revert to the default values stored in registers 30001 to 40000. p. 17, 18

Which racks does the SERI fit?

Register slot 1 of Class 8030 RRK-100, RRK200, RRK-300, HRK-100, HRK-150 or HRK-200 racks. p. 8

The whole text · 7 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 6561-65

The file

Revision and size

RevisionEffective 23 September, 2008
PublisherNiobrara Research & Development Corporation
Pages65
PDF442 KB
TextText from the PDF itself; page 22 is a scan, read by OCR, which may hold reading errors.