Manual · Telemecanique
ALTISTART 48 Soft Start Catalogue
Manual36 pagesPDF 3.6 MB
Product catalog for the Schneider Electric Altistart 48 (ATS48) soft starter for three-phase asynchronous motors.
What this file really is
The old site listed this file as a manual for the Telemecanique Altistart 48 ATS48. This is a product catalog for the Altistart 48 soft starter, not a user manual.
Filed under · 1 model
Filed under these models in the old catalog
Summary
What is in it
Schneider Electric's catalog for the ALTISTART 48 (ATS48) soft starter, a 6-thyristor controller for torque-controlled soft starting and stopping of three-phase squirrel cage motors. It gives applications and functions, technical characteristics (environment, electrical ratings, I/O, communication, protection, EMC), selection and voltage references, options, POWERSUITE dialog tools, dimensions, mounting, wiring diagrams, a description of the programmable functions and conventional starting curves.
Its parts
- Introduction
- Technical Characteristics
- Selection
- Voltage References
- Options
- POWERSUITE Advanced Dialog Solutions
- Dimensions
- Mounting
- Wiring Diagrams
- Functions
- Conventional Starting Curves
From the manual
Key facts from this manual
Each line names its page in the PDF.
Schneider Electric product catalogue (dated 09/02) for the ALTISTART 48 (ATS48) soft starter; despite its listing as a manual, it is a catalogue rather than an operating guide. It gives technical characteristics, selection and voltage references, options and accessories with catalog numbers, POWERSUITE programming tools, dimensions, mounting, wiring diagrams and the starter's functions.
- Device
- Soft starter with 6 thyristors for torque-controlled soft starting and stopping of three-phase squirrel cage asynchronous motors p. 3
- Line supply
- Three-phase 208 to 690 V, 50/60 Hz p. 3
- Starter current
- 17 to 1200 A nominal, across the range p. 4
- Control supply
- 110 - 15% to 230 + 10% V, 50/60 Hz p. 4
- Relay outputs
- 3 normally open relays R1, R2, R3, 1.8 A inductive at 230 Vac and 30 Vdc; factory set as fault, end of starting (bypass) and motor powered p. 4
- Logic I/O
- 4 isolated 24 V logic inputs (Stop, Run, LI3, LI4); 2 logic outputs LO1 and LO2, 200 mA max p. 5
- Analog output
- 0-20 mA or 4-20 mA, 500 Ω maximum load p. 5
- Communication
- Built-in RS-485 MODBUS link on an RJ45 connector, 4800, 9600 or 19200 bps, up to 18 starters p. 5
- Network gateways
- Ethernet bridge 174CEV30010; FIPIO gateway LUFP1; DEVICENET gateway LUFP9; PROFIBUS DP gateway LA9P307 p. 11
- Remote keypad
- VW3G48101, door-mounting kit with IP 54 seal and 9.82 ft (3 m) cable p. 14
- PC software
- POWERSUITE software workshop CD-ROM VW3A8104 and PC connection kit VW3A8106; version 1.30, build 5 or higher p. 3, 16
- Motor protection
- Built-in Class 10 motor thermal overload protection, plus a PTC probe input p. 3, 5
- Operating temperature
- -10 to 40 ˚C (14 to 104 ˚F) without derating; up to 60 ˚C with 2% current derating per ˚C above 40 ˚C p. 4
- Terminal covers
- LA9F702 for ATS48C14Y and C17Y; LA9F703 for ATS48C21Y, C25Y and C32Y p. 14
What this manual walks you through
- Technical characteristics: environment, electrical data, I/O and EMC p. 4, 5
- Connecting starters to a MODBUS network and to other buses p. 11
- Choosing the remote keypad, terminal covers and line reactors p. 14
- Setting up the starter with POWERSUITE on a Pocket PC or PC p. 15, 16
- Logic input functions: 2-wire and 3-wire control, external fault, second motor set p. 32
Good to know
- Power factor correction capacitors may only be used upstream of the starter and powered up at the end of starting. p. 5
- Each starter must be grounded, and separately when several share one line supply. p. 5
- Above 3300 ft (1000 m) the nominal current is derated 2.2% per 330 ft, to a maximum of 6600 ft (2000 m). p. 4
- Line reactors are recommended when several electronic starters share the same line supply. p. 14
Questions this manual answers
What motors can the Altistart 48 ATS48 soft starter control?
Three-phase squirrel cage asynchronous motors, on three-phase supplies of 208 to 690 V, 50/60 Hz. p. 3
Does the ATS48 support Modbus?
Yes: a built-in RS-485 MODBUS link on an RJ45 connector at 4800, 9600 or 19200 bps, with up to 18 starters on one link. p. 5
What is the part number of the ATS48 remote keypad display?
VW3G48101; it comes with a mounting kit and a 3 m cable with RJ45 and 9-pin SUB-D connectors. p. 14
Can the ATS48 be bypassed with a contactor after starting?
Yes. A contactor can bypass the starter at the end of starting while keeping electronic overload protection; relay R2 is set to control it. p. 3, 4
What PowerSuite version works with the ATS48?
The catalogue names the POWERSUITE software workshop, version 1.30, build 5 or higher. p. 3
The whole text · 4 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file

