Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Direct Communication Module (Cat. No. 1747-DCM) User Manual

Manual · Allen-Bradley

Direct Communication Module (Cat. No. 1747-DCM) User Manual

Manual80 pagesPDF 429 KB

User manual for the Allen-Bradley 1747-DCM Direct Communication Module, which links an SLC 500 to a supervisory PLC over the RIO link.

Download the PDF429 KB

Covers · 1 model

The models it covers

Summary

What is in it

Allen-Bradley's user manual for the 1747-DCM Direct Communication Module, used to connect an SLC 500 controller to a supervisory Allen-Bradley programmable controller over the RIO Link. It gives a hardware and system overview, a quick start for experienced users, addressing and image mapping, DIP switch configuration, installation and network wiring, programming with status words, troubleshooting with the front panel LEDs, application examples, specifications with throughput timing, and an addressing worksheet.

Its parts

  1. Preface
  2. Overview
  3. Quick Start for Experienced Users
  4. Addressing
  5. Module Configuration
  6. Installation and Wiring
  7. Programming
  8. Troubleshooting
  9. Application Examples

From the manual

Key facts from this manual

Each line names its page in the PDF.

Allen-Bradley user manual for the Direct Communication Module 1747-DCM, an SLC 500 Remote I/O adapter that lets supervisory processors such as PLC-5s and distributed SLC 500 processors exchange data over the RIO link. It covers scanner selection, DIP switch configuration, installation, network wiring, LED troubleshooting and specifications.

Read for this summary: pages 1 to 3, 15 to 17, 21 to 23, 31 to 37, 39 to 41, 53 to 54 and 65 to 66 of 80.

Device type
SLC 500 Remote I/O (RIO) adapter linking an SLC 500 to a supervisory Allen-Bradley controller; occupies one chassis slot p. 15, 16
Scanners
Works with all RIO scanners, including PLC processors with an integral RIO scanner and the 1771-SN or 1747-SN p. 16, 22
Rack sizes
1/4, 1/2, 3/4 or full logical rack: 2, 4, 6 or 8 words including the status word p. 32
Data rate, distance
57.6K baud up to 10,000 feet; 115.2K baud up to 5,000 feet; 230.4K baud up to 2,500 feet (Belden 9463) p. 65
Backplane current
360mA at 5V p. 39, 65
Operating temperature
0°C to 60°C (32°F to 140°F) p. 65
Storage temperature
−40°C to +85°C (−40°F to +185°F) p. 65
Humidity
5% to 95% noncondensing p. 65
Network cable
Belden 9463, daisy-chained; Line 1 blue, Line 2 clear, plus shield p. 16, 41
Termination
1/2 watt resistor across line 1 and line 2 at each end of the link; 82W 1/2 Watt at all baud rates with extended node capability p. 41
Indicators
FAULT LED (red) and COMM LED (green) p. 53
DIP switches
Two banks of eight: SW1 sets rack address and starting I/O group; SW2 sets data rate, clear on fault, last rack and rack size p. 31, 32, 33, 36, 37
Fixed SLC limit
Up to one DCM in a fixed SLC 500 2-slot expansion chassis, depending on the module in the second slot p. 39
DCM delay
Less than 10 msec p. 66

What this manual walks you through

  • Choosing a scanner and the logical rack size p. 22, 23
  • Setting the starting I/O group number p. 32
  • Setting the rack address for each scanner type p. 33, 34, 35
  • Setting rack size, last rack, clear on fault and data rate p. 36, 37
  • Installing and removing the DCM p. 40
  • Wiring and terminating the RIO link p. 41
  • Troubleshooting with the red FAULT LED p. 53
  • Troubleshooting with the green COMM LED p. 54
  • Working out maximum throughput time p. 66

Good to know

  • Disconnect power before installing, removing or wiring the DCM, and set the DIP switches before installing it. p. 39
  • The DCM image cannot cross logical rack boundaries: a 1/2 rack with starting group 6 is a configuration error. p. 36
  • Set SW2-4 to OFF when the DCM shares its logical rack and has the highest I/O group number in it. p. 36
  • With Clear On Fault set to ON, inputs hold their last state on a communication failure; check this is safe first. p. 37
  • Cover unused chassis slots with the 1746-N2 card slot filler. p. 40

Questions this manual answers

What does a blinking red FAULT LED mean on a 1747-DCM?

A configuration error: check the DIP switches, that the I/O group and rack size settings are compatible, and the rack address. p. 53

What does a blinking green COMM LED mean on a 1747-DCM?

The RIO scanner's processor is in Program/Test Fault Mode; correct that condition and cycle power to the DCM. p. 54

How long can the 1747-DCM RIO cable be?

With Belden 9463, up to 10,000 feet at 57.6K baud, 5,000 feet at 115.2K baud or 2,500 feet at 230.4K baud. p. 65

How much backplane current does the 1747-DCM draw?

360mA at 5 volts, so check that the SLC power supply has enough reserve. p. 39, 65

What terminating resistor does the 1747-DCM link need?

A 1/2 watt resistor across line 1 and line 2 at the scanner and at the last device; with extended node capability it is 82W 1/2 Watt at all baud rates. p. 41

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1747-6.8, Direct Communication Module User Manual1
  2. Important User Information2
  3. Summary of Changes3
    1. New Information3
  4. Preface9
    1. Who Should Use this Manual9
    2. Purpose of this Manual9
    3. Terms and Abbreviations12
    4. Common Techniques Used in this Manual13
    5. Allen–Bradley Support14
  5. 1 - Overview15
    1. Hardware Overview15
    2. System Overview16
    3. Scanner Image Division18
    4. Data Exchange Between RIO Scanners and the DCM20
  6. 2 - Quick Start for Experienced Users21
    1. Required Tools and Equipment21
    2. Procedures22
  7. 3 - Addressing25
    1. Addressing Ladder Logic Instructions25
    2. Image Mapping29
  8. 4 - Module Configuration31
    1. DIP Switches31
    2. DIP Switch 1 Settings32
    3. DIP Switch 2 Settings36
  9. 5 - Installation and Wiring39
    1. Compliance to European Union Directives39
    2. DCM Installation39
    3. Network Wiring41
  10. 6 - Programming43
    1. Overview43
    2. Programming Examples44
    3. Status Words47
    4. Applications Using I/O Status Word Bits49
  11. 7 - Troubleshooting53
    1. DCM Status Indicators53
    2. Troubleshooting Using the FAULT LED (Red)53
    3. Troubleshooting Using the COMM LED (Green)54
  12. 8 - Application Examples55
12 more lines, from page 55 on
  1. Basic Example55
    1. Supplementary Example58
  2. A - Specifications65
    1. Electrical Specifications65
    2. Environmental Specifications65
    3. Network Specifications65
    4. Throughput Timing66
  3. B - DCM Addressing Worksheet67
    1. Directions67
    2. Addressing Review67
  4. Index73
  5. Back Cover80

From the PDF’s own bookmarks.

The whole text · 12 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 41-4
  2. Table of Contents5-8
  3. Preface9-14
  4. 1 - Overview15-20
  5. 2 - Quick Start for Experienced Users21-24
  6. 3 - Addressing25-30
  7. 4 - Module Configuration31-38
  8. 5 - Installation and Wiring39-42
  9. 6 - Programming43-52
  10. Pages 53 to 6453-64
  11. Pages 65 to 7265-72
  12. Pages 73 to 8073-80

The file

Revision and size

RevisionPublication 1747-6.8, June 1996
PublisherAllen-Bradley
Pages80
PDF429 KB
TextText from the PDF itself.

The first pages · 3 of 80

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 80
Page 2
Page 2of 80
Page 3
Page 3of 80