Page 1 of Thermocouple/Millivolt Input Module (Cat. No. 1771-IXE Series D) User Manual

Manual · Allen-Bradley

Thermocouple/Millivolt Input Module (Cat. No. 1771-IXE Series D) User Manual

Manual85 pagesPDF 708 KB

User manual for the Allen-Bradley 1771-IXE Series D thermocouple/millivolt input module: installing, programming, calibrating and troubleshooting.

Download the PDF708 KB

Covers · 1 model

The models it covers

Summary

What is in it

Allen-Bradley user manual for the 1771-IXE Series D Thermocouple/Millivolt Input Module, an intelligent block transfer module for 1771 I/O chassis. It shows how to install the module and wire field devices, program block transfer reads and writes, configure input types, scaling, alarms and data format, read module status and input data, calibrate the channels, and troubleshoot with the status indicators. Appendices give specifications, sample programs for PLC-2, PLC-3 and PLC-5 processors, data table formats and differences between series.

Its parts

  1. Overview of the Thermocouple/Millivolt Input Module
  2. Installing the Thermocouple/Millivolt Input Module
  3. Module Programming
  4. Module Configuration
  5. Module Status and Input Data
  6. Module Calibration
  7. Troubleshooting

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

User manual (publication 1771-6.5.130, May 1999) for the Allen-Bradley 1771-IXE Series D thermocouple/millivolt input module for the 1771 I/O system. It explains installing and wiring the module, exchanging data with the processor by block transfer, calibrating it and troubleshooting it with the indicators and status bits.

Read for this summary: pages 1 to 5, 8 to 9, 11 to 13, 15 to 21 and 51 to 58 of 85.

Module type
Intelligent block transfer thermocouple/millivolt input module; single slot, no external power supply p. 11
Inputs
8 differential inputs, all of one type or 4 each of 2 types p. 11, 55
Input types
Thermocouple types E, J, K, R, S and T, or millivolt p. 55
Ranges E, J, K
Type E: -270 to 1000 C; Type J: -210 to 1200 C; Type K: -270 to 1380 C p. 56
Millivolt range
-100 to 100 mV p. 56
Resolution
1 C, 1 F, or 10uV p. 55
Data format
4-digit BCD, 2's complement binary or signed magnitude binary (selectable) p. 55
Wiring arm
1771-WI, 18-terminal p. 55
Keying
Between 20 and 22; between 24 and 26 p. 55
Input isolation
1000V peak between inputs, input and common, and input and backplane p. 55
Input update time
50ms total input update time, which is also the minimum interval between block transfer reads p. 11
Cold junction compensation
Range 0 to 60 C; accuracy +0.5 C as printed p. 55
Calibration
Auto-calibration of offset and gain; verify every six months p. 55
Overvoltage protection
120V rms, continuous p. 55

What this manual walks you through

  • Placing the module in the I/O chassis p. 17
  • Wiring thermocouples to the 1771-WI wiring arm p. 19
  • Grounding the shield of the sensor cable p. 20
  • Exchanging data with the processor by BTW and BTR block transfers p. 12
  • Reading the RUN and FAULT indicators p. 21
  • Troubleshooting with the LED chart p. 52
  • Monitoring status bits in words 1, 2, 3 and 13 p. 52, 53, 54
  • Estimating error from lead resistance and source impedance p. 57

Good to know

  • Do not use the module with the 1771-AL PLC-2/20 or 2/30 Local Adapter. p. 16
  • Do not insert or remove modules while system power is on. p. 17
  • The sensor cable must be shielded. p. 19
  • Recommended maximum cable length for voltage-mode input devices is 50 feet. p. 20
  • Readings are inaccurate when the module's ambient temperature is below 0 C or above 60 C. p. 52

Questions this manual answers

What thermocouple types does the 1771-IXE accept?

Types E, J, K, R, S and T, plus a millivolt input range. p. 55

Which wiring arm does the 1771-IXE use?

The 18-terminal 1771-WI field wiring arm, shipped with the module. p. 19, 55

What does a red FAULT LED on the 1771-IXE mean?

Right after power-up it indicates a RAM or EPROM failure; during operation, a possible microprocessor or backplane interface failure. The chart says to replace the module. p. 52

Why is the green RUN LED on the 1771-IXE flashing?

The module is powered but has not yet received its first (configuration) block transfer. p. 52

Which processors work with the 1771-IXE?

Any Allen-Bradley processor that uses the 1771 I/O structure and block transfer. p. 55

The whole text · 9 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 8581-85

The file

Revision and size

RevisionPublication 1771-6.5.130, May 1999
PublisherAllen-Bradley
Pages85
PDF708 KB
TextText from the PDF itself; 17 pages are scans, read by OCR, which may hold reading errors.