Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Pressure switch for gas DG, Technical Information

Manual · Kromschroder

Pressure switch for gas DG, Technical Information

Manual32 pagesPDF 3.0 MB

Technical information for the Kromschröder DG gas pressure switch series, including the DG..T: function, wiring, selection and data.

Download the PDF3.0 MB

Covers · 1 model

The models it covers

Summary

What is in it

Technical information for the Kromschröder DG pressure switch for gas and air, covering the DG..B, DG..U, DG..T, DG..H, DG..N, DG..I and DG..S versions. It shows application examples, certifications (EN 1854, SIL and PL, FM, UL and AGA for some versions), how positive, negative and differential pressure measurement works, connection diagrams and wiring, use in hazardous zones, the selection table and type code, installation, accessories, technical data, safety values, dimensions and maintenance cycles.

Its parts

  1. Application
  2. Certification
  3. Function
  4. Selection
  5. Project planning information
  6. Accessories
  7. Technical data
  8. Maintenance cycles

From the manual

Key facts from this manual

Each line names its page in the PDF.

Technical Information (edition 06.17) for the Kromschroder DG range of gas pressure switches, including the DG..T versions with NPT connections such as the DG 50T. It explains how the switch measures positive, negative and differential pressure, how to wire, select and install it, and lists accessories and technical data. It also gives safety characteristic values and maintenance cycles.

Read for this summary: pages 1 and 4 to 29 of 32.

What it is
DG..T: gas pressure switch for positive, negative and differential pressure, with NPT connections and a hand wheel scaled in "WC and mbar p. 4, 15
Switching capacity
DG..T: 30 – 240 V AC, 5 A at cos ϕ = 1, 0.5 A at cos ϕ = 0.6 p. 23
Pressure ports
DG..T: port 1 ¼" NPT (ports 1 and 2 available), port 4 ⅛" NPT p. 16
Electrical connection
DG..T: ½" NPT conduit cable gland; screw terminals for 0.5 to 1.8 mm wire (AWG 24 to AWG 13) p. 24
Temperature
DG..T: medium and ambient -40 to +60 °C (-40 to +140 °F); storage -20 to +40 °C (-4 to +104 °F) p. 23
Pilot lamp
DG..T: blue pilot lamp for 120 V AC fitted; DG..TG: red/green pilot LED for 24 V DC/AC p. 15
Gas types
Natural gas, town gas, LPG (gaseous), flue gas, biogas (max. 0.1%-by-vol. H2S) and air p. 23
Max test pressure
2 bar (29 psig) for less than 15 minutes, for testing the entire system p. 23
Weight
270 to 320 g (9.5 to 11.3 oz), depending on equipment p. 24
Enclosure
IP 54 or IP 65 p. 24
Materials
Silicone-free diaphragm (NBR, or IIR for DG..S); glass fibre reinforced PBT housing; AlSi 12 lower housing p. 23
Accessories
Weather protection cover 74924909; pressure equalization element 74923391; PIA test key 74329466; 5-piece filter pad set 74916199 p. 20, 22
Restrictor orifices
0.2 mm hole 75456321; 0.3 mm hole 75441317, for high pressure fluctuations p. 20
Approvals
The manual states DG..T is FM approved and UL approved (USA and Canada) p. 7

What this manual walks you through

  • Measuring positive, negative and differential pressure with the right ports p. 9
  • Wiring the contacts and pilot lamps p. 10, 11
  • Connecting the DG through an isolating amplifier, as the manual states for Zone 1 and 2 p. 12, 13
  • Choosing a model from the selection table and type code p. 15, 16
  • Installing the switch and correcting the switching point for its position p. 17
  • Installing outdoors and avoiding condensation p. 18
  • Adjusting ranges and switching differentials by type p. 25, 26
  • Calculating safety characteristic values for SIL and PL p. 27, 28

Good to know

  • Outside the vertical position the switching point shifts from the hand wheel value and must be checked. p. 17
  • Combustion gas or a gas and air mixture must not be connected to port 3 or 4. p. 17
  • Once a gold-contact unit has switched above the stated low-power limits, its gold plating is burnt through. p. 23
  • Maximum service life is 10 years after production plus up to half a year in storage, or the stated operating cycles. p. 27
  • Maintenance is due at least once a year, twice a year with biogas. p. 29

Questions this manual answers

What load can the DG50T pressure switch switch?

The DG..T switches 30 to 240 V AC at 5 A (cos ϕ = 1) or 0.5 A (cos ϕ = 0.6). p. 23

What temperature range is the DG..T rated for?

Medium and ambient -40 to +60 °C (-40 to +140 °F); storage and transport -20 to +40 °C. p. 23

What thread are the pressure connections on a DG..T?

Port 1 is ¼" NPT (ports 1 and 2 are available), and port 4 is ⅛" NPT. p. 16

How often should a DG gas pressure switch be serviced?

At least once a year, or twice a year when used with biogas. p. 29

Does it matter how the DG is mounted?

Yes. Only in the vertical position does the switching point match the hand wheel setting; otherwise it must be checked. p. 17

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Pressure switch for gas DG1
  2. 1 Application4
    1. 1.1 Application examples5
  3. 2 Certification7
    1. 2.1 Overview8
  4. 3 Function9
    1. 3.1 Positive pressure measurement9
    2. 3.2 Negative pressure measurement9
    3. 3.3 Differential pressure measurement9
    4. 3.4 Connection diagram10
    5. 3.5 Wiring11
    6. 3.6 DG in Zone 1 (21) and 2 (22) hazardous areas12
    7. 3.7 DG on pipes with Zone 2 (22) explosive atmospheres13
    8. 3.8 Animation14
  5. 4 Selection15
    1. 4.1 Selection table15
    2. 4.2 Type code16
  6. 5 Project planning information17
    1. 5.1 Installation17
  7. 6 Accessories19
    1. 6.1 Fastening set with screws, U-shape bracket19
    2. 6.2 Connecting set19
    3. 6.3 External adjustment19
    4. 6.4 Pressure equalization element20
    5. 6.5 Filter pad set20
    6. 6.6 Test key PIA20
    7. 6.7 Filter pad set20
    8. 6.8 Tube set21
    9. 6.9 Standard socket set21
    10. 6.10 Standard coupler plug21
    11. 6.11 Pilot lamp set, red or blue21
    12. 6.12 LED set, red/green21
    13. 6.13 Weather protection cover22
  8. 7 Technical data23
    1. 7.1 Adjusting range, switching hysteresis25
    2. 7.2 Safety-specific characteristic values for DG27
    3. 7.3 Dimensions29
  9. 8 Maintenance cycles29
  10. 9 Glossary30
16 more lines, from page 30 on
  1. 9.1 Diagnostic coverage DC30
    1. 9.2 Mode of operation30
    2. 9.3 Category30
    3. 9.4 Common cause failure CCF30
    4. 9.5 Fraction of undetected common cause failures β30
    5. 9.6 B10d value30
    6. 9.7 T10d value30
    7. 9.8 Hardware fault tolerance HFT31
    8. 9.9 Mean dangerous failure rate λD31
    9. 9.10 Safe failure fraction SFF31
    10. 9.11 Probability of dangerous failure PFHD31
    11. 9.12 Mean time to dangerous failure MTTFd31
    12. 9.13 Demand rate nop31
    13. 9.14 Average probability of dangerous failure on demand PFDavg31
  2. Feedback32
  3. Contact32

From the PDF’s own bookmarks.

The whole text · 4 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8
  2. Pages 9 to 169-16
  3. Pages 17 to 2417-24
  4. Pages 25 to 3225-32

The file

Revision and size

RevisionEdition 06.17
PublisherElster GmbH (Kromschröder)
Pages32
PDF3.0 MB
TextText from the PDF itself.

The first pages · 3 of 32

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 32
Page 2
Page 2of 32
Page 3
Page 3of 32

More documents · 1

For the same models