Page 1 of Class 8030 Types CRM-230, 232 Local/Remote Transfer Interface System

Manual · Square D

Class 8030 Types CRM-230, 232 Local/Remote Transfer Interface System

Manual46 pagesPDF 1.4 MB

Instruction bulletin for the Square D SY/MAX 8030 CRM-230 Local and CRM-232 Remote Transfer Interface modules for redundant processors.

Download the PDF1.4 MB

Covers · 2 models

The models it covers

Summary

What is in it

The Square D instruction bulletin for the Class 8030 CRM-230 Local Transfer Interface and CRM-232 Remote Transfer Interface modules, which together form the Transfer Interface System that lets redundant Primary and Backup SY/MAX processors control the I/O system. It covers specifications, LED indicators, communication channels, RTI DIP switches, installation and field wiring, power supplies, operation and rack addressing, system start-up and troubleshooting, with appendices on update times, control registers and error codes.

Its parts

  1. Introduction
  2. Specifications
  3. Description of Hardware
  4. Installation
  5. Operation
  6. System Start-Up

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Square D instruction bulletin 30598-251-01 (February 1987) for the Class 8030 Types CRM-230 Local Transfer Interface and CRM-232 Remote Transfer Interface of the SY/MAX programmable controller family. Together they form a Transfer Interface System that lets a Primary and a Backup processor share control of remote I/O and switch over on a fault. It covers specifications, LED meanings, DIP switch settings, installation, wiring, start-up, troubleshooting and error codes, with a 1990 addendum on older CRM230 modules.

Read for this summary: pages 1, 5 to 11, 21, 34 and 45 of 46.

What it is
Remote Transfer Interface (RTI) module of a Transfer Interface System that lets redundant Primary and Backup processors control the I/O p. 5
Current draw
CRM-232: 1.0 Amps @ 5 VDC from the SY/MAX power supply (CRM-230: 1.6 Amps @ 5 VDC) p. 5
Channels
CRM-232: two channels, A and B, wired to the I/O channels of the CPU A and CPU B Local Transfer Interfaces p. 8
Mounting
CRM-232: CPU slot (slot 1) of a digital or register I/O rack that is a drop, one per drop; not the LRK-100 Control Station I/O rack p. 6, 10
Processors
Model 500 (Series M or later) and Model 700 (Series C or later); not Model 300 p. 6
Transmission rate
I/O Channel 62.5K Baud; Register Transfer Channel 375K Baud p. 6
Cable and distance
Belden 8723 or equivalent two pair, twisted, shielded cable; I/O Channel 2500 feet (762 m) max, Register Transfer Channel 25 feet (7.6 m) max p. 10, 11
I/O capacity
Per LTI I/O Channel: 8 drops max, 1024 digital I/O max, 255 registers max; per drop: 128 digital I/O and 127 registers max p. 5
DIP switches
CRM-232: six switches on the rear; drop number select, terminator for processor A (switch 2) and processor B (switch 1); switch 6 not used p. 9, 10
Switchover time
3 CPU scans or 60 ms (whichever is greater) with the RTC link intact; 3 CPU scans or 250 ms if not synchronized and the RTC link is not intact p. 6
Operating temperature
0°C to 60°C (32° to 140° F); humidity 5% to 95% non-condensing p. 6
Dimensions
3.81 x 32.5 x 16.76 cm (W x H x D) p. 6
Weight
3.0 lbs (1.36 kg), approximate p. 6
Keying pin kit
Optional Class 8030 Type CBP-104 p. 9

What this manual walks you through

  • Reading the LTI and RTI LED indicators p. 7, 8
  • Using the LTI RESTART pushbutton in the Primary or Backup rack p. 8
  • Setting the RTI DIP switches for drop number and terminators p. 9, 10
  • Keying slots and placing the modules in the rack p. 9, 10
  • Wiring the I/O Channel daisy chain and the LTI-to-LTI Register Transfer Channel p. 10, 11
  • Arranging power supplies and branch circuits for redundancy p. 11
  • Power-up sequence for the Backup and Primary processors p. 21
  • Troubleshooting LED indications that differ at power-up p. 21
  • Understanding error code categories p. 34

Good to know

  • Remove power from the CPU and all I/O racks before inserting or removing any module or communication cable. p. 9
  • A star wiring configuration is not allowed anywhere on the I/O channel; wire it as a daisy chain. p. 10
  • If the CPU A and CPU B terminals are not wired consistently for each drop, the RTI gives error code 29510 and does not go to RUN. p. 10
  • A 1990 addendum warns that with CRM230 LTI modules Series D3 (no revision) and earlier, outputs may not follow the program after an I/O restart; it advises Series D3 Revision 2.0 or later. p. 45

Questions this manual answers

Which processors work with the 8030 CRM-232?

The Transfer Interface System works with Model 500 (Series M or later) and Model 700 (Series C or later) processors. It does not work with Model 300 processors. p. 6

Where does the CRM-232 Remote Transfer Interface go in the rack?

In the CPU slot (slot 1) of each rack that is a drop, with only one RTI per drop. p. 10

What cable and maximum distance does the CRM-232 use?

Belden 8723 or equivalent. The I/O Channel can run 2500 feet (762 m) and the Register Transfer Channel 25 feet (7.6 m). p. 11

How are the CRM-232 terminator switches set?

Only the last RTI on each LTI I/O Channel has its terminator switch ON: switch 2 for processor A, switch 1 for processor B. All other RTIs have them OFF. p. 10

Why does a new LTI show MODULE ERROR and error code 901?

The bulletin calls it normal for a new LTI, whose storage registers hold random data. Keyswitching the CPU from HALT to DISABLE OUTPUTS or RUN a second or third time clears it. p. 21

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Class 8030 Types CRM-230/2321
  2. Local/Remote Transfer1
  3. Interface System1
  4. Description1
  5. List of Figures4
  6. 1: Introduction5
    1. 1.1 General Information5
    2. 1.2 Summary of Operation5
  7. 2: Specifications5
    1. 2.1 General Information5
    2. 2.2 Electrical5
    3. 2.3 Environmental6
    4. 2.4 Physical6
  8. 3: Description of Hardware6
    1. 3.1 LED Indicators7
    2. 3.2 Communication Channels8
    3. 3.3 LTI Restart Pushbutton8
    4. 3.4 RTI DIP Switches9
  9. 4: Installation9
    1. 4.1 Inspection9
    2. 4.2 Module Keying9
    3. 4.3 Module Location10
    4. 4.4 Setting the RTI DIP Switches10
    5. 4.5 Installation in Rack Assembly10
    6. 4.6 Field Wiringˆ10
    7. 4.7 Power Supplies11
  10. 5: Operation12
    1. 5.1 General Description12
    2. 5.2 Local Transfer Interface Registers12
    3. 5.3 Rack Addressing13
    4. 5.4 Register Transfer Channel17
  11. 6: System Start-Up20
    1. 6.1 Preliminary Considerations20
    2. 6.2 Rack Addressing and Programming20
    3. 6.3 Power Up Sequence21
    4. 6.4 Troubleshooting21
  12. Appendices22
    1. A: LTI/RTI Update Time22
    2. B: LTI Control Registers23
6 more lines, from page 31 on
  1. C: Primary/Backup Determination31
    1. D: Example Transfer Interface System33
    2. E: Error Codes34
    3. F: Application Considerations42
    4. G: Additional Data Line Protection44
  2. Addendum (251-02B)45

From the PDF’s own bookmarks.

The whole text · 8 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 31-3
  2. Pages 4 to 84-8
  3. 4: Installation9-11
  4. 5: Operation, pages 12 to 1812-18
  5. 5: Operation, page 1919
  6. Pages 20 to 2820-28
  7. Pages 29 to 3729-37
  8. Pages 38 to 4638-46

The file

Revision and size

RevisionInstruction Bulletin 30598-251-01, February 1987
PublisherSquare D Company
Pages46
PDF1.4 MB
TextThe pages are scans; their text was read by OCR, which may hold reading errors.

The first pages · 3 of 46

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 46
Page 2
Page 2of 46
Page 3
Page 3of 46