Manual · AEG
Modicon 484 Programmable Controller Maintenance Manual
Manual160 pagesPDF 6.6 MB
Maintenance manual for the Modicon 484 programmable controller and its 500 series I/O modules, including the B553 and B557 input modules.
Covers · 8 models
The models it covers
Summary
What is in it
AEG Modicon's maintenance manual for the 484 programmable controller. It covers the processor, power supply, I/O section and P180 CRT programming panel, system installation and I/O addressing, programming (relays, latches, timers, counters, arithmetic, sequencers, MODBUS), the T158 telephone interface, L206 tape loader and J474 interface, troubleshooting with fault isolation flowcharts, and the 500 series I/O modules (B550 to B559) with schematics and terminal connections, plus the J470 adapter and J471 I/O expander.
Its parts
- 484 General Information
- Installation
- Operation
- Troubleshooting
- Service Center
- 500 Series I/O Devices
- J470 Adapter
- J471 I/O Expander
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Maintenance manual for the Modicon 484 Programmable Controller (ML-C484-MTN Rev B), covering installation, operation, troubleshooting and the 500 Series I/O modules. Among the modules it describes are the B553 Universal DC Input Module (True High) and the B557 VDC TTL Input Module, along with the rest of the B550 to B561 range, the J470 adapter and the J471 expander. Many pages are scans whose text runs out of order, so only clearly printed values are given here.
- B553 inputs
- B553: Universal DC input module (True High), four inputs sharing a common source, 9 to 56 volts DC, wired to positive VDC p. 120
- B553 levels
- B553: input ON above 60% of source voltage; about 0.75 mA at 24 VDC and 1.6 mA at 48 VDC; OFF to ON 7 ms max, ON to OFF 14 ms max p. 120, 121
- B557 inputs
- B557: VDC TTL input module, up to four independent +5 VDC inputs; the +5 V supply comes from the user p. 127, 128
- B557 levels
- B557: logic one with input high or open circuit; logic zero at 0.8V max; OFF to ON 4 ms max, ON to OFF 13 ms max p. 127, 128
- Matching output modules
- B557: works with the B556 and B236 output modules without extra components; B553: works with the Universal DC Output Module (True High) p. 121, 128
- Points per module
- 4 points per module, each with an LED and optical isolation; inputs filtered for spike rejection p. 114
- Field wiring
- Up to two #12 wires per terminal point; each I/O housing needs 5 inches of mounting width p. 112
- Operating temperature
- 500 Series I/O: 0 to 60 centigrade inside a standard NEMA cabinet, with free air flow p. 112
- Controllers
- 500 Series I/O connects directly to 484 controllers; with a suitable interface also to 184, 384 and 584 controllers p. 111
- Document
- Modicon 484 Programmable Controller maintenance manual, ML-C484-MTN Rev B p. 1, 11
- 484 controller
- Memory expandable in six sizes, 1/4K to 8K; scan 4 to 20 ms depending on memory size p. 11
What this manual walks you through
- Reading the electrical ratings of the B553 and B557 input modules p. 120, 121, 127, 128
- Setting I/O housing addresses with the switches on top of each housing p. 28, 29
- Finding and replacing blown output fuses p. 27
- Installing field wiring in the I/O housings p. 29
- Mounting the 484 processor and I/O housings p. 30, 31
Good to know
- Output fuses can only be replaced with the module removed from its housing. p. 27
- Two housings set to the same address must hold opposite module types: input in one, output in the other. p. 28
- On a power problem the controller shuts off the opto-isolator power, which forces all outputs off. p. 112
- B557: the maximum negative input voltage is -2 volts. p. 128
Questions this manual answers
What input voltage does the Modicon B553 take?
It is a True High universal DC input module for 9 to 56 volts DC, with the inputs wired to positive VDC. p. 120
What is the Modicon B557?
A VDC TTL input module with up to four independent +5 VDC inputs, powered by a 5 V supply from the user. p. 127, 128
Which output modules work with the B557?
The B556 and B236 output modules, without extra components. p. 128
How many I/O points does one 484 I/O channel take?
Up to 128 inputs and 128 outputs; a 484 with the optional I/O expander reaches 256 inputs and 256 outputs. p. 111
The whole text · 16 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 101-10
- Pages 11 to 2011-20
- Pages 21 to 3021-30
- Pages 31 to 4031-40
- Pages 41 to 5041-50
- Pages 51 to 6051-60
- Pages 61 to 7061-70
- Pages 71 to 8071-80
- Pages 81 to 9081-90
- Pages 91 to 10091-100
- Pages 101 to 110101-110
- Pages 111 to 120111-120
- Pages 121 to 130121-130
- Pages 131 to 140131-140
- Pages 141 to 150141-150
- Pages 151 to 160151-160
The file