Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Remote I/O Scanner 1747-SN User Manual

Manual · Allen-Bradley

Remote I/O Scanner 1747-SN User Manual

Manual171 pagesPDF 1.1 MB

User manual for the Allen-Bradley 1747-SN Remote I/O Scanner: installation, RIO link wiring, configuration and block transfers.

Download the PDF1.1 MB

Covers · 1 model

The models it covers

Summary

What is in it

User manual for the Allen-Bradley 1747-SN Remote I/O Scanner, the SLC module that exchanges discrete and block transfer data between an SLC processor and remote adapters on the RIO link. It explains how the scanner works, gives a quick start, covers installation, baud rate selection and RIO link wiring, configuration with G and M files in RSLogix 500, block transfer (BTR and BTW) programming, troubleshooting and error codes, and specifications with throughput calculations.

Its parts

  1. Overview
  2. Quick Start for Experienced Users
  3. Installation and Wiring
  4. Scanner Configuration and Programming
  5. RIO Block Transfer
  6. Troubleshooting

From the manual

Key facts from this manual

Each line names its page in the PDF.

Allen-Bradley user manual for the 1747-SN Remote I/O Scanner, the module that links an SLC 500 processor to remote chassis and devices over the Remote I/O link. It covers baud rate setup, installing the module, wiring the link, configuration and block transfers, status lights, error codes and specifications.

Read for this summary: pages 1 to 3, 9 to 11, 26 to 28, 35 to 43 and 95 to 98 of 171.

What it is
Remote I/O scanner for the SLC 500; master of the Remote I/O link p. 9
Processor
SLC 5/02 or later p. 9
Chassis slot
Any slot of the local SLC chassis except slot 0 p. 9
Capacity
Up to 4 logical racks (32 input and 32 output image words) p. 10
Baud rates
57.6, 115.2 or 230.4 Kbaud, set by DIP switch p. 26
Cable length
Belden 9463: 3048 m (10,000 ft) at 57.6K, 1524 m (5000 ft) at 115.2K, 762 m (2500 ft) at 230.4K baud p. 97
Backplane current
600 mA at 5V dc p. 97
Operating temperature
0 to 60 C (32 to 140 F) p. 97
Storage temperature
-40 to 85 C (-40 to 185 F) p. 97
Humidity
5 to 95% without condensation p. 97
Link connector
3-pin male; repair part number 1746-RT29 p. 27
Error codes
62H G file missing; 63H invalid configuration; 64H duplicate node; 68H to 6FH scanner hardware p. 96
Status lights
Red FAULT LED and red/green COMM LED p. 27
Slot filler
Card Slot Filler 1746-N2 for unused slots p. 37

What this manual walks you through

  • Setting the baud rate DIP switches p. 36
  • Inserting and removing the scanner in the SLC chassis p. 37, 38
  • Wiring the RIO link and terminating resistors p. 39
  • Grounding the cable shield, new installs and Series A retrofits p. 40, 41
  • Starting up the RIO system p. 41, 42
  • Reading the FAULT and COMM status LEDs p. 43
  • Troubleshooting by LED state and error code p. 95, 96
  • Checking retry counters in noisy environments p. 96
  • RIO network throughput p. 98

Good to know

  • All devices on the RIO link must use the same baud rate. p. 26
  • Extended node works only if every device on the link supports it. p. 39
  • Ground the RIO cable shield at the scanner end only. p. 41
  • Disconnect system power before installing, removing or wiring the scanner. p. 37
  • Block transfers may not work on adapters set to Hold Last State. p. 43

Questions this manual answers

What does error code 62H mean on a 1747-SN?

The G file is missing; enter the configuration information in the G file. p. 95

How much backplane current does the 1747-SN draw?

600 mA at 5V dc, so check that the SLC power supply has enough reserve. p. 37

How long can the 1747-SN remote I/O cable be?

Up to 3,048 meters (10,000 feet) end to end at 57.6K baud; shorter at higher baud rates. p. 10, 97

What part number is the 1747-SN RIO connector?

The 3-pin male RIO link connector has repair part number 1746-RT29. p. 27

What does a flashing green COMM LED mean on the 1747-SN?

At least one configured RIO link device is not communicating; check link connections, power and switch settings. p. 43, 95

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Important User Information2
  2. Summary of Changes3
  3. Overview9
    1. System Overview9
    2. How the Scanner Scans Remote I/O12
    3. How the Scanner Interacts with Adapters13
    4. Scanner I/O Image Concepts14
    5. Hardware Features26
  4. Quick Start for Experienced Users29
    1. Required Tools and Equipment29
    2. Procedures30
  5. Installation and Wiring35
    1. Compliance to European Union Directives35
    2. Baud Rate Selection36
    3. Scanner Installation36
    4. RIO Link Wiring39
    5. Start Up41
    6. Scanner Operation42
    7. Status LEDs43
  6. Scanner Configuration and Programming45
    1. Understanding Remote Input and Output Image Files45
    2. RIO Configuration Using G Files48
    3. Considerations When Configuring Remote I/O56
    4. Understanding M Files58
    5. Device Reset and Remote Output Reset Considerations65
    6. M1 Status File Description67
    7. RIO Communication Retry Counter (M1:e.16 -47)74
    8. Understanding Slot Addressing76
    9. SLC/Scanner Configuration77
  7. RIO Block Transfer79
    1. RIO Block Transfer Theory of Operation79
    2. Using Block Transfer Instructions (BTR and BTW)83
  8. Troubleshooting95
    1. Troubleshooting95
    2. Error Codes96
    3. Retry Counters96
    4. Block Transfers96
  9. Specifications97
    1. Scanner Operating Specifications97
13 more lines, from page 97 on
  1. Network Specifications97
    1. Throughput Introduction98
    2. Calculating Throughput99
  2. M0 - M1 Files and G Files113
    1. M0 - M1 Files113
    2. G Files121
  3. RIO Configuration Worksheet127
    1. Directions127
  4. Block Transfer Examples for Earlier Processors129
    1. BTR and BTW Control Logic Examples129
  5. Glossary161
  6. Index165
    1. Numerics165

From the PDF’s own bookmarks.

The whole text · 21 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 41-4
  2. Table of Contents5-8
  3. Overview, pages 9 to 189-18
  4. Overview, pages 19 to 2819-28
  5. Quick Start for Experienced Users29-34
  6. Installation and Wiring35-44
  7. Scanner Configuration and Programming, pages 45 to 5345-53
  8. Scanner Configuration and Programming, pages 54 to 6254-62
  9. Scanner Configuration and Programming, pages 63 to 7163-71
  10. Scanner Configuration and Programming, pages 72 to 7872-78
  11. RIO Block Transfer, pages 79 to 8679-86
  12. RIO Block Transfer, pages 87 to 9487-94
  13. Pages 95 to 10395-103
  14. Pages 104 to 112104-112
  15. M0 - M1 Files and G Files113-126
  16. Pages 127 to 135127-135
  17. Pages 136 to 144136-144
  18. Pages 145 to 153145-153
  19. Pages 154 to 160154-160
  20. Glossary161-164
  21. Index165-171

The file

Revision and size

Part no.1747-UM013B-EN-P
RevisionJanuary 2005
PublisherRockwell Automation
Pages171
PDF1.1 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.
1747-UM013B-EN-P

The first pages · 3 of 171

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 171
Page 2
Page 2of 171
Page 3
Page 3of 171