Page 1 of 1756 ControlLogix Communication Modules Specifications

Spec sheet · Allen-Bradley

1756 ControlLogix Communication Modules Specifications

Spec sheet34 pagesPDF 943 KB

Technical data for Allen-Bradley 1756 ControlLogix communication modules, including the 1756-DNB DeviceNet bridge module.

Download the PDF943 KB

Covers · 1 model

The models it covers

Summary

What is in it

Rockwell Automation technical data covering every 1756 ControlLogix communication module: EtherNet/IP bridges and web server, Stratix switches, ControlNet bridges, the 1756-DNB DeviceNet bridge, DH+ and Remote I/O modules, FOUNDATION Fieldbus linking devices, DH-485 and SynchLink. For each network it gives technical, environmental and certification specifications plus accessories. The DeviceNet section lists data rates, node count, current draw and connector details for the 1756-DNB/E.

Its parts

  1. Additional Resources
  2. Available Communication Modules
  3. EtherNet/IP Network
  4. Stratix Switches
  5. ControlNet Network
  6. DeviceNet Network
  7. DH+ and Remote I/O Networks
  8. FOUNDATION Fieldbus Network
  9. DH-485 Network
  10. SynchLink Communication

From the sheet

Key facts from this sheet

Each line names its page in the PDF.

Allen-Bradley technical data (publication 1756-TD003D-EN-E) for the 1756 ControlLogix communication modules: EtherNet/IP, ControlNet, DeviceNet, DH+ and Remote I/O, Foundation Fieldbus, DH-485 and SynchLink. For the 1756-DNB it gives the specifications of the series E module (1756-DNB/E), a DeviceNet bridge: data rates, node count, power draw, ports, chassis and power supplies, environment and certifications. It also describes the DeviceNet cable media.

Read for this summary: pages 1 to 2 and 17 to 19 of 34.

Module type
1756-DNB/E: DeviceNet bridge module for the ControlLogix chassis p. 2, 17
Data rates
1756-DNB/E: 125 Kbps (500 m max), 250 Kbps (250 m max), 500 Kbps (100 m max) p. 17
Nodes
1756-DNB/E: 64 max p. 17
Power draw
1756-DNB/E: 400 mA at 5.1V DC and 0 mA at 24V DC from the backplane; 60 mA at 24V DC from DeviceNet; DeviceNet voltage 11...25V DC p. 17
Ports
1756-DNB/E: one DeviceNet open-style 5- or 10-pin linear plug; USB 2.0 full speed (12 Mbps) p. 17
Chassis
1756-DNB/E: one slot, any slot of a 1756-A4, 1756-A7, 1756-A10, 1756-A13 or 1756-A17 chassis p. 17
Power supplies
Standard 1756-PA72/C, 1756-PA75/B, 1756-PB72/C, 1756-PB75/B, 1756-PC75/B, 1756-PH75/B; redundant 1756-PA75R, 1756-PB75R, 1756-PSCA2 p. 17
Operating temperature
0…60 °C (32…140 °F); storage -40…85 °C (-40…185 °F) p. 18
Isolation
50V continuous, DeviceNet network to backplane, type tested at 853V AC for 60 s; no isolation between USB and backplane p. 17
Power dissipation
3.5 W (11.9 BTU/hr) p. 17
Humidity, vibration, shock
5…95% noncondensing; 2 g at 10…500 Hz; 30 g operating, 50 g nonoperating shock p. 18
Connector torque
DeviceNet connector 0.56…0.79 N•m (5…7 lb•in) p. 17
Certifications
The spec sheet states UL and CSA listings, CE, C-Tick, FM approval and ODVA conformance, when the product is marked p. 19
Document
Rockwell Automation publication 1756-TD003D-EN-E, January 2012 p. 17

What this sheet walks you through

  • Checking the electrical and environmental specifications of the 1756-DNB/E p. 17, 18
  • Powering the DeviceNet network to meet CE low voltage and UL rules p. 17
  • Choosing DeviceNet cable: KwikLink Lite, KwikLink flat and round thick or thin trunk p. 19
  • Building a gateway between networks with several communication modules in one chassis p. 1
  • Comparing the ControlLogix communication modules by network p. 2

Good to know

  • The spec sheet states the USB port is for temporary local programming only, not a permanent connection, and must not be used in hazardous locations. p. 17
  • For CE compliance the DeviceNet network must be powered from an SELV or PELV source. p. 17
  • The module is open-style, with no enclosure type rating. p. 17

Questions this sheet answers

How many DeviceNet nodes does the 1756-DNB support?

The 1756-DNB/E supports up to 64 nodes. p. 17

What speeds and cable lengths does the 1756-DNB support?

125 Kbps up to 500 m, 250 Kbps up to 250 m and 500 Kbps up to 100 m (1756-DNB/E). p. 17

How much backplane current does the 1756-DNB draw?

The 1756-DNB/E draws 400 mA at 5.1V DC and 0 mA at 24V DC from the backplane. p. 17

Which chassis does the 1756-DNB fit?

The 1756-A4, 1756-A7, 1756-A10, 1756-A13 and 1756-A17 ControlLogix chassis, in any slot. p. 17

Does the 1756-DNB have a USB port?

The 1756-DNB/E has a USB 2.0 full speed port, meant only for temporary local programming. p. 17

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1756 ControlLogix Communication Modules Specifications Technical Data1
    1. Additional Resources2
    2. Available Communication Modules2
    3. EtherNet/IP Network3
    4. Stratix Switches9
    5. ControlNet Network10
    6. DeviceNet Network17
    7. DH+ and Remote I/O Networks20
    8. FOUNDATION Fieldbus Network25
    9. DH-485 Network28
    10. SynchLink Communication31
  2. Back Cover34

From the PDF’s own bookmarks.

The whole text · 4 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 91-9
  2. Pages 10 to 1810-18
  3. Pages 19 to 2719-27
  4. Pages 28 to 3428-34

The file

Revision and size

Part no.1756-TD003D-EN-E
RevisionJanuary 2012
PublisherRockwell Automation
Pages34
PDF943 KB
TextText from the PDF itself.
1756-TD003D-EN-E

The first pages · 4 of 34

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 34
Page 2
Page 2of 34
Page 3
Page 3of 34
Page 4
Page 4of 34

More documents · 1

For the same models