Allen-Bradley product data for the 1771 digital I/O relay contact output modules. A general section explains the benefits of relay outputs, the three relay types (electromechanical, dry-reed and mercury-wetted), system compatibility, power supply requirements, keying, status indicators, application considerations, output module loading and certifications. A second section gives module-specific information for the 1771-OW, -OW16, -OWN, -OWNA, -OX, -OYL and -OZL.

Its parts

  1. Benefits
  2. Using This Publication
  3. Relay Types
  4. System Compatibility
  5. Power Supply Requirements
  6. Keying
  7. Status Indicators
  8. Application Considerations
  9. Output Module Loading
  10. Compliance to European Union Directives
  11. Agency Certification
  12. Module Information
  13. Support Services

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Allen-Bradley publication 1771-2.181 on 1771 digital I/O relay contact output modules: the 1771-OW, -OW16, -OWN, -OWNA, -OX, -OYL and -OZL. A general section explains relay types, chassis compatibility, keying, snubbers and relay life, and each module then has its own pages with a schematic, wiring and specifications. The module facts here come from the 1771-OZL pages.

Read for this summary: pages 1 to 7 and 25 to 29 of 32.

What it is
1771-OZL: 0-24V relay contact output module with 8 normally-open (Form A) dry-reed relays p. 3, 27
Outputs
1771-OZL: 8, in 4 groups of 2, each with its own common p. 27
Voltage rating
1771-OZL: 0-24V ac rms; 0-24V dc p. 28
Current rating
1771-OZL: 100mA per output (maximum) p. 28
Power rating
1771-OZL: 2.4W per output (resistive), dc and suppressed ac p. 28
Minimum contact load
1771-OZL: dc 1mA @ 0-24V; ac 1mA @ 0-24V p. 28
Backplane current
1771-OZL: 420mA maximum p. 28
Isolation voltage
1771-OZL: 1000V between open contacts; 1500V between coil and contact p. 28
Timing
1771-OZL: operate/release 1ms maximum; bounce 1ms maximum p. 28
Power dissipation
1771-OZL: 2.2 Watts (max.), 2 Watts (min.) p. 28
Driving inputs
1771-OZL: can drive an ac input module up to 24V ac p. 27
Installation data
1771-OZL: publication 1771-2.129 p. 28, 29
Relay type
Dry-reed in the 1771-OYL and -OZL; electromechanical in the -OW, -OW16, -OWN and -OWNA; mercury-wetted in the -OX p. 3
Snubber parts
5%, 1 Watt carbon composition resistor; capacitor ac rating above the maximum voltage across the contacts p. 6

What this manual walks you through

  • Choosing between electromechanical, dry-reed and mercury-wetted relays p. 3
  • Chassis compatibility, power supply loading and keying p. 4
  • Relay life, response time and capacitive loading of long cables p. 5
  • Sizing an RC snubber network across the contacts p. 6
  • Derating for incandescent lamp loads p. 7
  • Wiring the 1771-OZL outputs p. 27
  • Driving a 1771-IND ac input module with the 1771-OZL p. 27, 28

Good to know

  • The 1771-OZL has no surge limiting and is for resistive loads only, such as lamps, indicators and heating elements. p. 27
  • Do not wire outputs in parallel to raise the current or wattage rating. p. 27
  • The 1771-OW, -OW16, -OWN, -OWNA, -OYL and -OZL are not UL/CSA approved for reactive loads. p. 6
  • Dry-reed relays cannot handle surge currents. p. 3
  • Relays can run below the minimum current and voltage, but not reliably. p. 7

Questions this manual answers

What kind of relays are in the 1771-OZL?

Eight normally-open (Form A) dry-reed relays. p. 3, 27

What voltage and current can the 1771-OZL switch?

0-24V ac rms or 0-24V dc, up to 100mA per output. p. 28

What is the difference between the 1771-OYL and 1771-OZL?

The 1771-OYL has 4 normally-open and 4 normally-closed relays; the 1771-OZL has 8 normally-open relays. p. 25, 27

Can the 1771-OZL switch motor starters or solenoids?

No. It is recommended for resistive loads only, not inductive or capacitive loads such as motor starters, solenoids or relays. p. 27

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1771-2.181, Digital I/O Relay Contact Output Modules1
  2. Benefits2
  3. Using This Publication2
  4. Relay Types3
  5. System Compatibility4
  6. Power Supply Requirements4
  7. Keying4
  8. Status Indicators4
  9. Application Considerations5
  10. Output Module Loading7
  11. Compliance to European Union Directives12
  12. Agency Certification12
  13. Module Information13
  14. Support Services31
  15. Back Cover32

From the PDF’s own bookmarks.

The whole text · 6 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 31-3
  2. Pages 4 to 64-6
  3. Output Module Loading7-11
  4. Pages 12 to 1812-18
  5. Pages 19 to 2519-25
  6. Pages 26 to 3226-32

The file

Revision and size

RevisionPublication 1771-2.181, September 1997
PublisherAllen-Bradley
Pages32
PDF1.3 MB
TextText from the PDF itself; pages 9, 10 and 30 are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 32

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 32
Page 2
Page 2of 32
Page 3
Page 3of 32