Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of SLC 500 4-Channel Analog I/O Modules User Manual

Manual · Allen-Bradley

SLC 500 4-Channel Analog I/O Modules User Manual

Manual113 pagesPDF 1.2 MB

User manual for the Allen-Bradley SLC 500 4-channel analog I/O modules: 1746-NI4, NIO4I, NIO4V, NO4I and NO4V.

Download the PDF1.2 MB

Covers · 1 model

The models it covers

Summary

What is in it

User manual for the SLC 500 4-channel analog I/O modules, catalog numbers 1746-NI4, 1746-NIO4I, 1746-NIO4V, 1746-NO4I and 1746-NO4V. It covers a quick start, power requirements, configuring, installing and wiring the modules, grounding and noise, how the module exchanges data with the processor, testing, programming examples for addressing, scaling and range checking, maintenance and safety, full specifications, two's complement numbers, optional input calibration and the input and output circuits.

Its parts

  1. Preface
  2. 1 - Overview
  3. 2 - Quick Start for Experienced Users
  4. 3 - Installing and Wiring Your Analog Module
  5. 4 - Module Operation and System Considerations
  6. 5 - Testing Your Module
  7. 6 - Programming Examples
  8. 7 - Maintenance and Safety

From the manual

Key facts from this manual

Each line names its page in the PDF.

Allen-Bradley user manual for the SLC 500 4-channel analog I/O modules 1746-NI4, 1746-NIO4I, 1746-NIO4V, 1746-NO4I and 1746-NO4V. It covers installing and wiring the modules, addressing and converting their data, startup testing, ladder examples for scaling inputs and outputs, and the specifications.

Read for this summary: pages 1 to 3, 5 to 7, 13 to 14, 39 to 41, 44 to 45, 47 to 49, 57, 60 and 91 to 92 of 113.

Device
1746-NI4: analog input module with 4 channels, voltage or current selectable per channel p. 14
Input type
1746-NI4: 4 differential inputs, not individually isolated p. 14
Input ranges
±10V dc, 0 to 10V dc, 0 to 5V dc, 1 to 5V dc, ±20 mA, 0 to 20 mA, 4 to 20 mA p. 44
Resolution
16 significant bits, 305.176 µV per LSB on the ±10V dc range p. 44
Backplane current
1746-NI4: 35 mA at 5V, 85 mA at 24V (max.) p. 14
Module ID code
1746-NI4: 4401 p. 39
Image table
1746-NI4: 4 input words, channels 0 to 3 at words 0 to 3 p. 40
Input converter
16 bit, delta-sigma modulation; 10 Hz channel bandwidth; 60 ms step response at 95% p. 92
Input impedance
1746-NI4: 380K ohms to ANL COM (Series B and greater; 500K ohms for Series A) p. 92
Update time
512 µs for all channels in parallel p. 91
Isolation
500V dc, field wiring to backplane p. 91
Cable and wire
Shielded Belden #8761; #14 AWG maximum; removable terminal block p. 91
Common mode range
-20 to +20 volts p. 92
Data format
16-bit two's complement binary p. 44

What this manual walks you through

  • Quick start for experienced users p. 5
  • Entering the module ID code when configuring the slot p. 39
  • Addressing the input and output words p. 40, 41
  • Converting input values to volts or milliamps p. 44, 45
  • Retentive and non-retentive analog outputs p. 47, 48
  • Programming input out-of-range detection p. 49
  • Powering up and checking the module LED p. 57
  • Finding why an input channel fails startup testing p. 60
  • Scaling with the SCL and SCP instructions p. 6
  • Optional software calibration of an input channel p. 7

Good to know

  • The modules send no input out-of-range signal to the processor. p. 49
  • A dark module LED means the module is not working; a lit LED alone does not prove it works. p. 57
  • In normal operation a voltage source should not be wired to an input set for current. p. 60
  • Analog outputs are forced to 0 volts or 0 mA whenever the system is not in RUN mode. p. 47
  • On the Hand-Held Terminal or DTAM, data shows in decimal only after it is moved to an integer file. p. 44

Questions this manual answers

What is the module ID code for the 1746-NI4?

4401, entered when the programming software gives no module list. p. 39

How do I convert a 1746-NI4 input value to volts?

Multiply the input value by 10V divided by 32,768; the result is approximate, within the module's accuracy. p. 44

How do I convert a 1746-NI4 input value to milliamps?

Multiply the input value by 20 mA divided by 16,384; for example 4096 is about 5 mA. p. 45

Why is the LED on my 1746-NI4 off?

The manual lists four likely causes: no power to the SLC system, power not reaching the rest of the system, a bad chassis slot, or a defective module. p. 57

Does the 1746-NI4 detect out-of-range inputs?

No. If that matters, the processor can be programmed to check the input values. p. 49

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1746-UM005B-EN-P, SLC 500 4-Channel Analog I/O Modules User Manual1
  2. Important User Information2
  3. Summary of Changes3
  4. Preface9
    1. Who Should Use this Manual9
    2. Purpose of this Manual9
    3. Common Techniques Used in this Manual11
  5. 1 - Overview13
    1. How to Use Analog13
    2. Types of Analog Modules13
  6. 2 - Quick Start for Experienced Users15
    1. Required Tools and Equipment15
    2. Procedures16
  7. 3 - Installing and Wiring Your Analog Module23
    1. European Union Directive Compliance23
    2. Determining Your Power Requirements for a Modular Controller24
    3. Determining Your Power Requirements for a Fixed Controller24
    4. Configuring Your Module27
    5. Choosing a Slot in the Chassis28
    6. Installing Your Module28
    7. Wiring Considerations30
    8. Wiring the Analog Module32
    9. Labeling and Installing the Terminal Block34
    10. Grounding the Foil Shields and Drain Wires34
    11. Minimizing Electrical Noise on Analog Modules37
  8. 4 - Module Operation and System Considerations39
    1. Interface between the Module and the Processor39
    2. System Considerations47
  9. 5 - Testing Your Module55
    1. Testing the SLC 500 System55
  10. 6 - Programming Examples63
    1. Addressing, Out-of-Range Detection, and Scaling of Analog Inputs63
    2. Addressing and Scaling Outputs70
    3. Scaling Offset when > 32,767 or < -32,76876
    4. Scaling and Range Checking and Analog Inputs and Outputs82
    5. Scaling and Range Checking of Analog Inputs and Outputs86
  11. 7 - Maintenance and Safety89
    1. Preventative Maintenance89
    2. Safety Considerations When Troubleshooting90
15 more lines, from page 91 on
  1. A - Specifications91
    1. Analog Modules Specification91
    2. General Specifications for NI4, NIO4I, NIO4V, NO4I, and NO4V91
    3. General Analog Input Specifications for NI4, NIO4I, and NIO4V92
    4. Current-Loop Input Specifications for NI4, NIO4I, and NIO4V93
    5. Voltage Input Specifications for NI4, NIO4I, and NIO4V94
    6. Current Output Specifications for NIO4I and NO4I95
    7. Voltage Output Specifications for NIO4V and NO4V96
  2. B - Two’s Complement Binary Numbers97
  3. C - Optional Analog Input Software Calibration101
    1. Calibrating an Analog Input Channel101
  4. D - Module Input and Output Circuits107
  5. Index109
    1. Numerics109
  6. Back Cover113

From the PDF’s own bookmarks.

The whole text · 16 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 41-4
  2. Table of Contents5-8
  3. Preface9-12
  4. Pages 13 to 2213-22
  5. 3 - Installing and Wiring Your Analog Module, pages 23 to 3023-30
  6. 3 - Installing and Wiring Your Analog Module, pages 31 to 3831-38
  7. 4 - Module Operation and System Considerations, pages 39 to 4639-46
  8. 4 - Module Operation and System Considerations, pages 47 to 5447-54
  9. 5 - Testing Your Module55-62
  10. 6 - Programming Examples, pages 63 to 7163-71
  11. 6 - Programming Examples, pages 72 to 8072-80
  12. 6 - Programming Examples, pages 81 to 8881-88
  13. Pages 89 to 9689-96
  14. B - Two’s Complement Binary Numbers97-100
  15. C - Optional Analog Input Software Calibration101-106
  16. Pages 107 to 113107-113

The file

Revision and size

Part no.1746-UM005B-EN-P
RevisionJune 2004
PublisherRockwell Automation
Pages113
PDF1.2 MB
TextText from the PDF itself.
1746-UM005B-EN-P

The first pages · 3 of 113

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 113
Page 2
Page 2of 113
Page 3
Page 3of 113

More documents · 1

For the same models