Manual · Allen-Bradley
1747-SDN DeviceNet Scanner Module User Manual
Manual160 pagesPDF 3.9 MB
User manual for the Allen-Bradley 1747-SDN DeviceNet Scanner Module (Series C), which links DeviceNet devices to an SLC 500 processor.
Covers · 1 model
The models it covers
Summary
What is in it
The user manual for the Allen-Bradley 1747-SDN DeviceNet Scanner Module, catalog number 1747-SDN Series C. It explains what the module does, how to plan the configuration and map device data, set up the hardware, configure the DeviceNet network and scanlist with RSLinx and RSNetWorx, reach DeviceNet from Ethernet or DH+, build and run an example program, troubleshoot with the status indicators and numeric codes, and use explicit messaging and AutoScan. Appendices cover data maps, M0/M1 files and firmware history.
Its parts
- Before You Begin
- Planning Your Configuration and Data Mapping Your Devices
- Hardware Setup
- Configuring the DeviceNet Network
- Communicating with the DeviceNet Network from Another Network
- Creating and Running the Example Application Program
- Troubleshooting
- DeviceNet Explicit Messaging
- AutoScan
From the manual
Key facts from this manual
Each line names its page in the PDF.
User manual (publication 1747-UM655B-EN-P, June 2007) for the Allen-Bradley 1747-SDN DeviceNet scanner module, series C, which links an SLC 500 processor to DeviceNet devices. It walks through hardware setup, building the scanlist with RSNetWorx for DeviceNet, pass-through access from Ethernet or DH+, an example program, explicit messaging, AutoScan and troubleshooting by status codes.
- What it is
- DeviceNet scanner module linking an SLC 500 processor to DeviceNet devices p. 14
- Series covered
- 1747-SDN, Series C p. 1
- Processor data exchange
- M1/M0 file transfers and/or discrete I/O p. 14
- Device messaging
- Strobe, poll, change of state and cyclic messages p. 16
- Network connector
- 10-pin linear plug in the DeviceNet port on the module front p. 40, 42
- Chassis slot
- Any slot of the SLC 500 chassis except the leftmost (processor) slot p. 41
- Status display
- Bicolor (green/red) MODULE and NET indicators plus a two-digit numeric display p. 89, 90
- Normal display codes
- 0 to 63 shows the node address; 65 is normal operation with AutoScan enabled p. 91
- Fault codes
- 70 duplicate node address; 72 slave stopped communicating; 78 slave not present; 91 bus-off; 92 no network power; E9 memory flushed to factory defaults p. 91, 92
- Configuration tool
- RSNetWorx for DeviceNet through a 1770-KFD RS-232 interface or a 1784-PCD, 1784-PCID or 1784-PCIDS PC card p. 20
- Configuration storage
- Scanner configuration table and scanlist table kept in nonvolatile memory p. 19
- Pass-through needs
- RSLinx 2.10 or later, module firmware 4.015 or later, M0 and M1 files set to 395 words p. 64
- Series C firmware
- Revision 8.002 adds an embedded EDS file and AutoScan p. 129
- Cables in example
- 1787-RSCABL/A (computer to 1770-KFD); DeviceNet cables 1787-PCABL, 1787-TCABL, 1787-MCABL p. 10
What this manual walks you through
- Installing the module in an SLC 500 chassis p. 41
- Wiring the module to the DeviceNet network p. 42
- Configuring the module's data tables with RSNetWorx for DeviceNet p. 20
- Reaching DeviceNet devices from an Ethernet or DH+ network by pass-through p. 9
- Building an example program for a photoeye and a RediSTATION p. 9
- Reading the status indicators and numeric codes p. 90
- Setting up AutoScan to map devices without RSNetWorx p. 103
- Firmware revision history and known anomalies p. 129
Good to know
- Do not install the module with the chassis power supply on; it may damage the module. p. 41
- Do not wire the module with the network power supply on; it may short the network. p. 42
- AutoScan needs a series C module. p. 103
- Do not disconnect the module during a flash update (code 95), or the data in its memory is lost. p. 92
- Firmware revisions 7.005 and 7.006 have known anomalies, such as failed flash updates with a 98 error. p. 129
Questions this manual answers
What does code 92 mean on a 1747-SDN display?
No network power is detected on the communication port. Provide network power and make sure the drop cable supplies it to the module. p. 92
What does code 70 mean on a 1747-SDN?
The module failed the duplicate node address check. Change it to a node address not already in use. p. 91
Which chassis slot can the 1747-SDN go in?
Any slot except the leftmost one, which is reserved for the SLC 500 processor. p. 41
Can a 1747-SDN build its scanlist without RSNetWorx?
Yes, on a series C module with firmware 8.002 the AutoScan feature maps the devices into the scanlist. p. 129
What does a solid red MODULE light on a 1747-SDN mean?
The module has an unrecoverable fault, and the manual says to replace it. p. 89
Contents
Chapters and sections
Each line opens the PDF at its page.
- 1747-UM655B-EN-P, 1747-SDN DeviceNet Scanner Module User Manual1
- Important User Information2
- Summary of Changes3
- Preface9
- 1 - Before You Begin13
- 2 - Planning Your Configuration and Data Mapping Your Devices23
- 3 - Hardware Setup31
- What This Chapter Contains31
- Installing the 1770-KFD Module31
- Installing the SLC 500 Processor32
- Installing the ControlNet RS-232 Interface Module35
- Installing the 1747-SDN Module40
- Installing the RediSTATION Operator Interface43
- Installing the Series 9000 Photoeye44
- How Your Network Will Look45
- What’s Next?46
- 4 - Configuring the DeviceNet Network47
48 more lines, from page 62 on
- What’s Next?62
- 5 - Communicating with the DeviceNet Network from Another Network63
- 6 - Creating and Running the Example Application Program79
- 7 - Troubleshooting89
- 8 - DeviceNet Explicit Messaging93
- 9 - AutoScan103
- A - Data Map Example115
- B - Configuring the M0/M1 Files by Using RSLogix 500 Software121
- C - 1747-SDN Module Firmware History129
- D - Data Organization133
- E - Explicit Message Program Control143
- Glossary153
- Index157
- Back Cover160
The whole text · 22 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 41-4
- Table of Contents5-8
- Preface9-12
- 1 - Before You Begin13-22
- 2 - Planning Your Configuration and Data Mapping Your Devices23-30
- 3 - Hardware Setup, pages 31 to 3831-38
- 3 - Hardware Setup, pages 39 to 4639-46
- 4 - Configuring the DeviceNet Network, pages 47 to 5447-54
- 4 - Configuring the DeviceNet Network, pages 55 to 6255-62
- 5 - Communicating with the DeviceNet Network from Another Network, pages 63 to 7063-70
- 5 - Communicating with the DeviceNet Network from Another Network, pages 71 to 7871-78
- 6 - Creating and Running the Example Application Program79-88
- 7 - Troubleshooting89-92
- 8 - DeviceNet Explicit Messaging93-102
- 9 - AutoScan103-114
- A - Data Map Example115-120
- B - Configuring the M0/M1 Files by Using RSLogix 500 Software121-128
- C - 1747-SDN Module Firmware History129-132
- D - Data Organization133-142
- E - Explicit Message Program Control143-152
- Glossary153-156
- Pages 157 to 160157-160