Manual · Allen-Bradley
ControlLogix Digital I/O Modules User Manual
Manual258 pagesPDF 7.2 MB
User manual for Allen-Bradley ControlLogix 1756 digital I/O modules, including the 1756-OB16E fused DC output module.
Covers · 1 model
The models it covers
Summary
What is in it
The Rockwell Automation user manual for the ControlLogix 1756 digital input and output modules, from the 1756-IA8D to the 1756-OX8I, including the 1756-OB16E electronically-fused DC output module. It explains how the modules work in a ControlLogix system (ownership, connections, local and remote chassis), their common, diagnostic and fast features, how to install and key the removable terminal block, how to configure the modules, and gives a wiring diagram for each module, plus troubleshooting and tag definitions.
Its parts
- Preface
- What Are ControlLogix Digital I/O Modules?
- Digital I/O Operation in the ControlLogix System
- Common Module Features
- Diagnostic Module Features
- Fast Module Features
- Install ControlLogix I/O Modules
- Configure ControlLogix Digital I/O Modules
- Wiring Diagrams
From the manual
Key facts from this manual
Each line names its page in the PDF.
This is the Rockwell Automation user manual for ControlLogix digital I/O modules (publication 1756-UM058I-EN-P, December 2017). It covers about forty 1756 input and output modules, from the 1756-IA8D to the 1756-OX8I, including the 1756-OB16E electronically fused DC output module. It explains how the modules work, how to install, wire, configure and troubleshoot them.
- Module type
- ControlLogix 10…31.2V DC 16-point electronically fused output module p. 13, 164
- Output protection
- Electronically fused; at currents over 4 A the trip time can be as fast as 20uS p. 140, 164
- Output groups
- Two groups (Group 0 and Group 1), with supply terminals DC-0(+) and DC-1(+) p. 164
- Signal delay
- 270 μs worst case at 24V DC and 25 °C (typically 70 μs hardware plus 200 μs ASIC scan) p. 20
- Connection formats
- CST Timestamped Fuse Data with Output Data or Scheduled Output Data, plus a Listen Only version p. 135
- Fault reporting
- Module-fault word (Fault tag) and fuse blown word (FuseBlown tag) p. 59
- Fault and Program states
- Per point: hold last state, on, or off (off is default) p. 140
- Scheduled outputs
- Synchronization within 16.7 seconds maximum, referenced to Coordinated System Time p. 140
- Keying
- Electronic module keying, software configurable; user-defined mechanical RTB keying p. 140
- Terminal blocks
- Not included; RTB types 1756-TBCH cage clamp, 1756-TBNH NEMA clamp, 1756-TBSH or TBS6H spring clamp p. 12, 119
- Extended-depth housing
- 1756-TBE, for heavy gauge wiring; standard-depth housing comes with the RTB p. 123
What this manual walks you through
- Installing the module, keying, wiring and fitting the removable terminal block p. 113
- Wiring a cage clamp terminal block p. 119
- Choosing standard-depth or extended-depth housing p. 123
- Choosing a communication format for an output module p. 135
- Reading fault words in program logic p. 59, 60
- 1756-OB16E wiring diagram and trip time charts p. 164, 165
- Troubleshooting with the status indicators p. 179, 180
Good to know
- Electronic protection is not meant to replace fuses, circuit breakers or other code-required wiring protection. p. 52
- The 1756-OB16E has no protection against reverse polarity wiring or wiring to AC power sources. p. 52
- Open-type equipment for a Pollution Degree 2 industrial environment, to be mounted in a suitable enclosure; up to 2000 m without derating. p. 113
- The manual points to publication 1756-TD002 for the latest I/O module specifications. p. 140
Questions this manual answers
What voltage does the 1756-OB16E output module switch?
It is a 10…31.2V DC, 16-point electronically fused output module. p. 13
What does a red FUSE light on a ControlLogix output module mean?
A short overload fault has occurred for a point in that group. Check the wiring, then reset the fuse in the Module Properties dialog box in the Logix Designer application. p. 180
Does the 1756-OB16E need external fuses?
It is electronically fused, but the manual states that electronic protection does not replace fuses, circuit breakers or other code-required wiring protection. p. 52
Which terminal block fits the 1756-OB16E?
The module needs a removable terminal block or a 1492 wiring interface module, ordered separately. RTB types are 1756-TBCH, 1756-TBNH, 1756-TBSH and TBS6H. p. 12, 119
What does a steady red OK light mean on a 1756 output module?
The module must be replaced. p. 180
Contents
Chapters and sections
Each line opens the PDF at its page.
- ControlLogix Digital I/O Modules User Manual1
- Important User Information2
- Preface9
- 1 - What Are ControlLogix Digital I/O Modules?11
- 2 - Digital I/O Operation in the ControlLogix System17
- 3 - Common Module Features35
- 4 - Diagnostic Module Features61
- 5 - Fast Module Features77
- 6 - Install ControlLogix I/O Modules113
- 7 - Configure ControlLogix Digital I/O Modules129
- 8 - Wiring Diagrams139
- A - Troubleshoot Your Module179
- B - Tag Definitions185
- C - Use Ladder Logic To Perform Run Time Services and Reconfiguration217
- D - Choose a Correct Power Supply235
- E - Motor Starters for Digital I/O Modules237
- F - Major Revision Upgrades239
- G - 1492 IFMs for Digital I/O Modules241
- Index251
- Back Cover256
The whole text · 27 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- ControlLogix Digital I/O Modules User Manual, pages 1 to 101-10
- ControlLogix Digital I/O Modules User Manual, pages 11 to 2011-20
- ControlLogix Digital I/O Modules User Manual, pages 21 to 3021-30
- ControlLogix Digital I/O Modules User Manual, pages 31 to 4031-40
- ControlLogix Digital I/O Modules User Manual, pages 41 to 5041-50
- ControlLogix Digital I/O Modules User Manual, pages 51 to 6051-60
- ControlLogix Digital I/O Modules User Manual, pages 61 to 7061-70
- ControlLogix Digital I/O Modules User Manual, pages 71 to 8071-80
- ControlLogix Digital I/O Modules User Manual, pages 81 to 9081-90
- ControlLogix Digital I/O Modules User Manual, pages 91 to 10091-100
- ControlLogix Digital I/O Modules User Manual, pages 101 to 110101-110
- ControlLogix Digital I/O Modules User Manual, pages 111 to 120111-120
- ControlLogix Digital I/O Modules User Manual, pages 121 to 130121-130
- ControlLogix Digital I/O Modules User Manual, pages 131 to 140131-140
- ControlLogix Digital I/O Modules User Manual, pages 141 to 150141-150
- ControlLogix Digital I/O Modules User Manual, pages 151 to 160151-160
- ControlLogix Digital I/O Modules User Manual, pages 161 to 170161-170
- ControlLogix Digital I/O Modules User Manual, pages 171 to 180171-180
- ControlLogix Digital I/O Modules User Manual, pages 181 to 190181-190
- ControlLogix Digital I/O Modules User Manual, pages 191 to 200191-200
- ControlLogix Digital I/O Modules User Manual, pages 201 to 210201-210
- ControlLogix Digital I/O Modules User Manual, pages 211 to 220211-220
- ControlLogix Digital I/O Modules User Manual, pages 221 to 230221-230
- ControlLogix Digital I/O Modules User Manual, pages 231 to 240231-240
- ControlLogix Digital I/O Modules User Manual, pages 241 to 250241-250
- ControlLogix Digital I/O Modules User Manual, pages 251 to 255251-255
- Back Cover256-258