Allen-Bradley 1775-P3
Technical specifications:
Input Voltage: 115V AC, 230V AC
Input Voltage Range: 115V AC: 97 to 132V AC, 230V AC: 194 to 264V AC
Input Current: 115V AC: 3.0A @ 97V AC, 230V AC: 1.5A @ 194V AC
Frequency Range: 47 to 63Hz
Output Voltage @ Rated Current: +5V DC: 28A 16V DC: 1A (total)
Overcurrent Shutdown Limit: 125% of rated current
Input Power: 210W(nom)
Fuses: (2) 5A, 250 Volt, Slow Blow
Power Interlock Relay Contacts Rating: 1A maximum, 250V maximum
Terminal Strip Wire Size: 14AWG (max.)
External Transformer Rating (if used): 1000VA maximum (1 kVA)
Name:
Address:
1201 S. Second Street
Milwaukee, WI 53204
United States
Phone:
414-382-8410
Web site:
Support phone:
1-440-646-3434
Support site:
cab-bat-pow-acc