Manual · Omron
SYSMAC C200H Programmable Controllers (CPU21-E/23-E/31-E) Installation Guide
Manual186 pagesPDF 1.6 MB
Installation guide for OMRON C200H PLCs with CPU21-E/23-E/31-E, with specifications for I/O units such as the C200H-OD212 and OD218.
Covers · 2 models
The models it covers
Summary
What is in it
OMRON's installation guide for C200H C-series Programmable Controllers using the C200H-CPU21-E, CPU23-E or CPU31-E. It describes every unit of the system, how to assemble and mount it, I/O word allocation and remote I/O, the installation environment, power and safety considerations, and replacing fuses, relays and batteries. Appendices list standard models and give unit specifications, including the C200H-OD212 16-point and C200H-OD218 32-point transistor output units.
Its parts
- Precautions
- Section 1 Introduction
- Section 2 Unit Description
- Section 3 Assembly Instructions
- Section 4 System Connections
- Section 5 Installation Environment
- Section 6 Power Considerations
- Section 7 Safety Considerations
- Section 8 Inspection and Maintenance
- Appendix A Standard Models
- Appendix B Specifications
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
An installation guide for SYSMAC C200H programmable controllers built on the C200H-CPU21-E, C200H-CPU23-E and C200H-CPU31-E CPU Units. It covers the whole system: mounting units, I/O word allocation, wiring, the installation environment, and replacing fuses, relays and batteries. Its appendix lists the standard models and gives specifications for each I/O unit, among them the C200H-OD212 and C200H-OD218 transistor output units.
- C200H-OD212 outputs
- C200H-OD212: transistor output unit, 16 points on one common, 0.3 A at 24 VDC per point (4.8 A per unit) p. 113
- C200H-OD218 outputs
- C200H-OD218: transistor output unit, 32 points on one common, 16 mA at 4.5 VDC to 100 mA at 26.4 VDC p. 129
- C200H-OD212 backplane
- C200H-OD212: mounts only on a C200H-BC031-V1/V2, C200H-BC051-V1/V2, C200H-BC081-V1/V2 or C200H-BC101-V1/V2 backplane p. 45, 81
- C200H-OD218 CPUs
- C200H-OD218: a Group-2 High-density I/O Unit; mounts only with a C200H-CPU21-E/23-E/31-E or on an Expansion I/O Rack, never on a Slave Rack p. 29, 41
- C200H-OD212 power
- C200H-OD212: 180 mA at 5 VDC internal; external 24 VDC supply of 35 mA min. p. 113
- C200H-OD218 power
- C200H-OD218: 180 mA at 5 VDC internal; external 5 to 24 VDC supply of 110 mA min. (3.4 mA per ON point) p. 129
- C200H-OD212 fuse
- C200H-OD212: 8 A 125 V fuse (5.2 dia. x 20), UL-TSC-8A-N1 (Nagasawa); no blown-fuse detector p. 113
- C200H-OD218 fuse
- C200H-OD218: 3.5 A fuse, not user-replaceable p. 129
- C200H-OD212 response
- C200H-OD212: ON 0.2 ms max., OFF 0.3 ms max.; leakage 0.1 mA max.; residual voltage 1.4 V max. p. 113
- C200H-OD218 response
- C200H-OD218: ON 0.1 ms max., OFF 0.4 ms max.; leakage 0.1 mA max.; residual voltage 0.8 V max. p. 129
- C200H-OD212 size
- C200H-OD212: B-shape unit, 350 g max. p. 113
- C200H-OD218 I/O words
- C200H-OD218: C-shape units take 2 words in IR 030 to IR 049, starting at IR 030 + 2 x the I/O number switch setting p. 29, 129
What this manual walks you through
- Mounting I/O Units on the Backplane next to the CPU Unit p. 37
- Fitting a Memory Unit into the CPU Unit p. 41
- Setting the I/O number of a Group-2 High-density I/O Unit p. 29
- Working out I/O word allocation for each rack p. 45
- Checking the current each unit draws from the 5-V supply p. 51
- Replacing output unit fuses p. 75
- Replacing the Battery Set in a RAM Unit p. 78, 79
- Model numbers of backplanes, CPU Units, Memory Units, power supplies and I/O cables p. 80
- Wiring the C200H-OD212 terminals p. 113
Good to know
- C200H-OD212: 24 VDC must be supplied to terminal B9, or current leaks through the load while the output is OFF. p. 113
- Mounted on any backplane other than the V1/V2 models named for it, the C200H-OD212 will not operate properly. p. 37
- A changed I/O number is recognized only after the PC is turned off, and no two units may share an I/O word. p. 29
- Replace the battery within one week of the BATT FAIL message, and finish the swap within five minutes so data is kept. p. 78
- The manual shows two circuit versions of the C200H-OD218: units made on or before January 28th, 2000, and on or after January 31st, 2000. p. 130
Questions this manual answers
Which backplane does the C200H-OD212 need?
It must be mounted on a C200H-BC031-V1/V2, C200H-BC051-V1/V2, C200H-BC081-V1/V2 or C200H-BC101-V1/V2 backplane. p. 45, 81
What is the output rating of the C200H-OD212?
16 transistor outputs on one common, each switching 0.3 A at 24 VDC, with 4.8 A per unit. p. 113
Which CPU Units work with the C200H-OD218?
As a Group-2 High-density I/O Unit it mounts only with a C200H-CPU21-E, CPU23-E or CPU31-E or on an Expansion I/O Rack, not on a Slave Rack. p. 29, 41
Can I replace the fuse in a C200H-OD218?
No. Its 3.5 A fuse is not user-replaceable. p. 129
What fuse does the C200H-OD212 take?
An 8 A 125 V fuse, 5.2 dia. x 20, listed as UL-TSC-8A-N1 (Nagasawa). The unit has no blown-fuse detector. p. 113
Contents
Chapters and sections
Each line opens the PDF at its page.
- Front1
- C200H Programmable Controllers Installation Guide (For CPU21-E/23-E/31-E)2
- Notice:3
- About this Manual:6
- PRECAUTIONS7
- SECTION 1 Introduction11
- SECTION 2 Unit Description18
- SECTION 3 Assembly Instructions35
- SECTION 4 System Connections43
- SECTION 5 Installation Environment60
- SECTION 6 Power Considerations66
The whole text · 25 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 31-3
- Pages 4 to 64-6
- PRECAUTIONS7-10
- SECTION 1 Introduction11-17
- SECTION 2 Unit Description, pages 18 to 2618-26
- SECTION 2 Unit Description, pages 27 to 3427-34
- SECTION 3 Assembly Instructions35-42
- SECTION 4 System Connections, pages 43 to 5143-51
- SECTION 4 System Connections, pages 52 to 5952-59
- SECTION 5 Installation Environment60-65
- SECTION 6 Power Considerations66-69
- SECTION 7 Safety Considerations70-73
- SECTION 8 Inspection and Maintenance74-79
- Appendix, pages 80 to 8980-89
- Appendix, pages 90 to 9990-99
- Appendix, pages 100 to 109100-109
- Appendix, pages 110 to 119110-119
- Appendix, pages 120 to 129120-129
- Appendix, pages 130 to 139130-139
- Appendix, pages 140 to 149140-149
- Appendix, pages 150 to 159150-159
- Appendix, pages 160 to 169160-169
- Appendix, pages 170 to 177170-177
- Glossary178-182
- Pages 183 to 186183-186