Page 1 of DX-9100 Configuration Guide

Manual · Johnson Controls

DX-9100 Configuration Guide

Manual288 pagesPDF 1.3 MB

Configuration guide for the Johnson Controls DX-9100 Extended Digital Plant Controller, Versions 1, 2 and 3.

Download the PDF1.3 MB

Covers · 1 model

The models it covers

Summary

What is in it

The configuration guide for the Johnson Controls DX-9100 Extended Digital Plant Controller, covering all three versions including the DX-912x LONWORKS version. It summarizes the hardware inputs and outputs, then explains software configuration: analog and digital inputs and outputs, extension modules, network points, the control and calculation algorithms, time schedules, optimal start/stop, programmable logic control, trend log, diagnostics and download/upload, with item tables in the appendices.

Its parts

  1. DX-9100 Extended Digital Plant Controller
  2. Software Configuration
  3. Appendix A: SX Tool Item Description and Tables
  4. Appendix B: Item Structure
  5. Appendix C: Programmable Function Module Items
  6. Appendix D: Logic Variables
  7. Appendix E: Analog Items and Logic Variables for the Trend Log Module

From the manual

Key facts from this manual

Each line names its page in the PDF.

This is the Johnson Controls DX-9100 Configuration Guide (LIT-6364030) for the DX-9100 Extended Digital Plant Controller. It covers all three versions, including the DX-912x LONWORKS version, and explains how to set up inputs, outputs, extension modules, control algorithms, schedules and logic with the GX-9100 software or the SX-9120 service module. It also covers diagnostics, power-up behavior and downloading or uploading a configuration.

Read for this summary: pages 1 to 14, 42 to 44 and 204 to 208 of 288.

Device
Digital plant controller for chiller, boiler, HVAC air handling and lighting control p. 5
Power
24 VAC; 50 Hz or 60 Hz set by software configuration p. 10
Analog inputs
8; 0-10 VDC or 0-20 mA, or Nickel 1000, Pt1000 or A99 passive RTD sensors, chosen by jumpers p. 10
Digital inputs
8, for voltage-free contacts p. 10
Digital outputs
6 isolated triac outputs switching external 24 VAC circuits p. 10
Analog outputs
Version 1: 2 (0-10 VDC or 0-20 mA, 4-20 mA by configuration); Versions 2 and 3: 4 of those plus 4 at 0-10 VDC only p. 10
Supervisory bus
Versions 1 and 2: N2 Bus (Bus 91) RS-485; Version 3: LONWORKS N2 Bus, up to 30 controllers per bus p. 10
Expansion
XT Bus (RS-485) for up to 8 XT-9100 or XTM-905 extension modules, 64 inputs/outputs at most p. 7, 10
Other ports
SX-9120 service module port; Versions 2 and 3: RS-232-C port for local download and upload p. 10, 207
Software modules
12 programmable function modules, a logic control module with 64 logic results, 8 time schedules, 2 optimal start/stop modules p. 11
Configuration tools
GX-9100 Graphic Configuration Software (Version 5 or later) on a PC; SX-9120 Service Module (Version 3.1 or later) p. 7
Version 3 network points
Version 3: up to 16 network analog inputs, 16 analog outputs, 8 digital inputs and 8 digital outputs p. 8
Download converter
RS-232-C/RS-485 converter MM-CVT101-x (North America) or IU-9100-810x (Europe) p. 206
Model numbers
Version 1: DX-9100-8154; Version 2: DX-9100-8454; Version 3: DX-912x-8454 p. 6

What this manual walks you through

  • Overview of the hardware inputs, outputs and ports p. 10
  • The order of steps for configuring the controller p. 14
  • Entering data and connecting modules in the GX Tool p. 12, 13, 14
  • Configuring XT-9100 and XTM-905 extension modules p. 42, 43, 44
  • Setting up PID, on/off and calculation algorithms p. 1, 2
  • Reading the controller diagnostic flags p. 204
  • Choosing how outputs and supervisory commands behave at power up p. 204, 205
  • Downloading and uploading a configuration over the N2 Bus or RS-232-C port p. 206, 207, 208

Good to know

  • Do not download an untested configuration into an installed controller; test it on a simulator panel first. p. 207
  • Controlled devices should be isolated during download and initial startup. p. 207
  • Values above 2047 may be rounded by 0.1% by the communications bus protocol. p. 12
  • The controller sends commands to an extension module only when both hold identical configuration data. p. 44
  • If an extension module uses points on a second XP expansion module, the next extension module cannot be configured. p. 44

Questions this manual answers

What power supply does the DX-9100 need?

It must be supplied with 24 VAC, and it suits 50 Hz or 60 Hz through software configuration. p. 10

What software is used to configure the DX-9100?

The GX-9100 Graphic Configuration Software (Version 5 or later) on a PC; changes can also be made with an SX-9120 Service Module. p. 7

How many extension modules can a DX-9100 take?

Up to eight XT-9100 or XTM-905 extension modules on the XT Bus, for up to 64 extra inputs and outputs. p. 7

Which sensors can the DX-9100 analog inputs read?

0-10 VDC or 0-20 mA active sensors, or Nickel 1000, Pt1000 or A99 passive RTD sensors, selected by jumpers. p. 10

How does the DX-9100 show a low internal battery?

The BATLOW diagnostic variable is set when the internal lithium battery falls to about 20% of its capacity. p. 204

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. DX-9100 Extended Digital Plant Controller5
    1. Introduction5
    2. Hardware Configuration10
  2. Software Configuration11
    1. DX-9100 Software Elements11
    2. Configuration Tools11
    3. Configuring the Controller14
    4. DX-9100 Controller Selection15
    5. DX-9100 Global Data15
    6. Configuration Number (Version 1.1 or Later)17
    7. Password Feature (Versions 1.4, 2.3, 3.3, or Later)17
    8. Analog Input Configuration18
    9. Digital Input Configuration25
    10. Analog Output Configuration26
    11. Digital Output Configuration32
    12. DO: Output Type34
    13. Constants and Result Status40
    14. Extension Module Configuration42
    15. Network Analog Input Configuration (Version 3 Only)51
    16. Network Digital Input Configuration (Version 3 Only)52
    17. Network Analog Output Configuration (Version 3 Only)53
    18. Network Digital Output Configuration (Version 3 Only)55
    19. Programmable Function Module Configuration57
    20. Control Algorithm Theory63
    21. Algorithm 01 - PID Control Module65
    22. Algorithm 02 - On/Off Control Module78
    23. Algorithm 03 - Heating/Cooling PID Control Module (Dual€PID)86
    24. Algorithm 04 - Heating/ Cooling On/Off Control Module (Dual On/Off)98
    25. Numerical Calculation and Other Function Module Configurations107
    26. Algorithm 11 - Average107
    27. Algorithm 12 - Minimum Select109
    28. Algorithm 13 - Maximum Select111
    29. Algorithm 14 - Psychrometric Calculation ˚C113
    30. Algorithm 15 - Psychrometric Calculation ˚F116
    31. Algorithm 16 - Line Segment119
    32. Algorithm 17 - Input Selector121
    33. Algorithm 18 - Calculator123
    34. Algorithm 19 - Timer Functions125
    35. Algorithm 20 - Totalization129
    36. Algorithm 21 - Comparator133
56 more lines, from page 136 on
  1. Algorithm 22 - Sequencer136
    1. Algorithm 23 – Four Channel Line Segment (Version 1.1 or Later)152
    2. Algorithm 24 – Eight Channel Calculator (Version 1.1 or Later)154
    3. Time Program Functions156
    4. Time Schedule Configuration157
    5. Optimal Start/Stop Configuration161
    6. Programmable Logic Control Configuration174
    7. Dial-up Feature with an NDM188
    8. Trend Log (Versions 1.4, 2.3, 3.3, or Later)192
    9. Supervisory Mode Control Settings (General Module)195
    10. Controller Diagnostics204
    11. Power Up Conditions204
    12. Download/ Upload206
    13. Calibration Values209
  2. Appendix A: SX Tool Item Description and Tables211
    1. Description of Items211
    2. Item List213
    3. Floating Point Numbers215
    4. EEPROM Items215
  3. Appendix B: Item Structure217
    1. General Module Items Structure217
    2. Programmable Function Module Items Structure223
    3. Analog Input Module Items Structure226
    4. Analog Output Module Items Structure228
    5. Digital Output Module Items Structure229
    6. Extension Module Items Structure230
    7. Time Scheduling Items Structure236
    8. Optimal Start/Stop Items Structure237
    9. Network Information Module Items Structure238
    10. Network Digital Output Module Items Structure239
    11. Network Analog Output Module Items Structure241
    12. Network Digital Input Module Items Structure243
    13. Network Analog Input Module Items Structure244
  4. Appendix C: Programmable Function Module Items247
    1. Algorithm 1 - PID Controller247
    2. Algorithm 2 - On/Off Controller249
    3. Algorithm 3 - Heating/Cooling PID Controller251
    4. Algorithm 4 - Heating/Cooling On/Off Controller253
    5. Algorithm 11 - Average Calculation256
    6. Algorithm 12 - Minimum Selection257
    7. Algorithm 13 - Maximum Selection258
    8. Algorithm 14 - Psychrometric Calculation ˚C259
    9. Algorithm 15 - Psychrometric Calculation ˚F260
    10. Algorithm 16 - Line Segment Function261
    11. Algorithm 17 - Input Selector262
    12. Algorithm 18 - Calculator263
    13. Algorithm 19 - Timer Function264
    14. Algorithm 20 - Totalization266
    15. Algorithm 21 – Eight Channel Comparator269
    16. Algorithm 22 - Sequencer271
    17. Algorithm 23 – Four Channel Line Segment Function274
    18. Algorithm 24 – Eight Channel Calculator276
  5. Appendix D: Logic Variables279
    1. Description of Logic Variables279
    2. Logic Variable Tables280
  6. Appendix E: Analog Items and€Logic Variables for the Trend Log Module287

From the PDF’s own bookmarks.

The whole text · 31 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 41-4
  2. DX-9100 Extended Digital Plant Controller5-10
  3. Software Configuration, pages 11 to 2011-20
  4. Software Configuration, pages 21 to 3021-30
  5. Software Configuration, pages 31 to 4031-40
  6. Software Configuration, pages 41 to 5041-50
  7. Software Configuration, pages 51 to 6051-60
  8. Software Configuration, pages 61 to 7061-70
  9. Software Configuration, pages 71 to 8071-80
  10. Software Configuration, pages 81 to 9081-90
  11. Software Configuration, pages 91 to 10091-100
  12. Software Configuration, pages 101 to 110101-110
  13. Software Configuration, pages 111 to 120111-120
  14. Software Configuration, pages 121 to 130121-130
  15. Software Configuration, pages 131 to 140131-140
  16. Software Configuration, pages 141 to 150141-150
  17. Software Configuration, pages 151 to 160151-160
  18. Software Configuration, pages 161 to 170161-170
  19. Software Configuration, pages 171 to 180171-180
  20. Software Configuration, pages 181 to 190181-190
  21. Software Configuration, pages 191 to 200191-200
  22. Software Configuration, pages 201 to 210201-210
  23. Appendix A: SX Tool Item Description and Tables211-216
  24. Appendix B: Item Structure, pages 217 to 226217-226
  25. Appendix B: Item Structure, pages 227 to 236227-236
  26. Appendix B: Item Structure, pages 237 to 246237-246
  27. Appendix C: Programmable Function Module Items, pages 247 to 254247-254
  28. Appendix C: Programmable Function Module Items, pages 255 to 262255-262
  29. Appendix C: Programmable Function Module Items, pages 263 to 270263-270
  30. Appendix C: Programmable Function Module Items, pages 271 to 278271-278
  31. Pages 279 to 288279-288

The file

Revision and size

RevisionCode No. LIT-6364030, Issue Date 0900
PublisherJohnson Controls
Pages288
PDF1.3 MB
TextText from the PDF itself.

The first pages · 3 of 288

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 288
Page 2
Page 2of 288
Page 3
Page 3of 288