Manual · Johnson Controls
DX-9100 Configuration Guide
Manual288 pagesPDF 1.3 MB
Configuration guide for the Johnson Controls DX-9100 Extended Digital Plant Controller, Versions 1, 2 and 3.
Covers · 1 model
The models it covers
Summary
What is in it
The configuration guide for the Johnson Controls DX-9100 Extended Digital Plant Controller, covering all three versions including the DX-912x LONWORKS version. It summarizes the hardware inputs and outputs, then explains software configuration: analog and digital inputs and outputs, extension modules, network points, the control and calculation algorithms, time schedules, optimal start/stop, programmable logic control, trend log, diagnostics and download/upload, with item tables in the appendices.
Its parts
- DX-9100 Extended Digital Plant Controller
- Software Configuration
- Appendix A: SX Tool Item Description and Tables
- Appendix B: Item Structure
- Appendix C: Programmable Function Module Items
- Appendix D: Logic Variables
- Appendix E: Analog Items and Logic Variables for the Trend Log Module
From the manual
Key facts from this manual
Each line names its page in the PDF.
This is the Johnson Controls DX-9100 Configuration Guide (LIT-6364030) for the DX-9100 Extended Digital Plant Controller. It covers all three versions, including the DX-912x LONWORKS version, and explains how to set up inputs, outputs, extension modules, control algorithms, schedules and logic with the GX-9100 software or the SX-9120 service module. It also covers diagnostics, power-up behavior and downloading or uploading a configuration.
- Device
- Digital plant controller for chiller, boiler, HVAC air handling and lighting control p. 5
- Power
- 24 VAC; 50 Hz or 60 Hz set by software configuration p. 10
- Analog inputs
- 8; 0-10 VDC or 0-20 mA, or Nickel 1000, Pt1000 or A99 passive RTD sensors, chosen by jumpers p. 10
- Digital inputs
- 8, for voltage-free contacts p. 10
- Digital outputs
- 6 isolated triac outputs switching external 24 VAC circuits p. 10
- Analog outputs
- Version 1: 2 (0-10 VDC or 0-20 mA, 4-20 mA by configuration); Versions 2 and 3: 4 of those plus 4 at 0-10 VDC only p. 10
- Supervisory bus
- Versions 1 and 2: N2 Bus (Bus 91) RS-485; Version 3: LONWORKS N2 Bus, up to 30 controllers per bus p. 10
- Expansion
- XT Bus (RS-485) for up to 8 XT-9100 or XTM-905 extension modules, 64 inputs/outputs at most p. 7, 10
- Other ports
- SX-9120 service module port; Versions 2 and 3: RS-232-C port for local download and upload p. 10, 207
- Software modules
- 12 programmable function modules, a logic control module with 64 logic results, 8 time schedules, 2 optimal start/stop modules p. 11
- Configuration tools
- GX-9100 Graphic Configuration Software (Version 5 or later) on a PC; SX-9120 Service Module (Version 3.1 or later) p. 7
- Version 3 network points
- Version 3: up to 16 network analog inputs, 16 analog outputs, 8 digital inputs and 8 digital outputs p. 8
- Download converter
- RS-232-C/RS-485 converter MM-CVT101-x (North America) or IU-9100-810x (Europe) p. 206
- Model numbers
- Version 1: DX-9100-8154; Version 2: DX-9100-8454; Version 3: DX-912x-8454 p. 6
What this manual walks you through
- Overview of the hardware inputs, outputs and ports p. 10
- The order of steps for configuring the controller p. 14
- Entering data and connecting modules in the GX Tool p. 12, 13, 14
- Configuring XT-9100 and XTM-905 extension modules p. 42, 43, 44
- Setting up PID, on/off and calculation algorithms p. 1, 2
- Reading the controller diagnostic flags p. 204
- Choosing how outputs and supervisory commands behave at power up p. 204, 205
- Downloading and uploading a configuration over the N2 Bus or RS-232-C port p. 206, 207, 208
Good to know
- Do not download an untested configuration into an installed controller; test it on a simulator panel first. p. 207
- Controlled devices should be isolated during download and initial startup. p. 207
- Values above 2047 may be rounded by 0.1% by the communications bus protocol. p. 12
- The controller sends commands to an extension module only when both hold identical configuration data. p. 44
- If an extension module uses points on a second XP expansion module, the next extension module cannot be configured. p. 44
Questions this manual answers
What power supply does the DX-9100 need?
It must be supplied with 24 VAC, and it suits 50 Hz or 60 Hz through software configuration. p. 10
What software is used to configure the DX-9100?
The GX-9100 Graphic Configuration Software (Version 5 or later) on a PC; changes can also be made with an SX-9120 Service Module. p. 7
How many extension modules can a DX-9100 take?
Up to eight XT-9100 or XTM-905 extension modules on the XT Bus, for up to 64 extra inputs and outputs. p. 7
Which sensors can the DX-9100 analog inputs read?
0-10 VDC or 0-20 mA active sensors, or Nickel 1000, Pt1000 or A99 passive RTD sensors, selected by jumpers. p. 10
How does the DX-9100 show a low internal battery?
The BATLOW diagnostic variable is set when the internal lithium battery falls to about 20% of its capacity. p. 204
Contents
Chapters and sections
Each line opens the PDF at its page.
- DX-9100 Extended Digital Plant Controller5
- Software Configuration11
- DX-9100 Software Elements11
- Configuration Tools11
- Configuring the Controller14
- DX-9100 Controller Selection15
- DX-9100 Global Data15
- Configuration Number (Version 1.1 or Later)17
- Password Feature (Versions 1.4, 2.3, 3.3, or Later)17
- Analog Input Configuration18
- Digital Input Configuration25
- Analog Output Configuration26
- Digital Output Configuration32
- DO: Output Type34
- Constants and Result Status40
- Extension Module Configuration42
- Network Analog Input Configuration (Version 3 Only)51
- Network Digital Input Configuration (Version 3 Only)52
- Network Analog Output Configuration (Version 3 Only)53
- Network Digital Output Configuration (Version 3 Only)55
- Programmable Function Module Configuration57
- Control Algorithm Theory63
- Algorithm 01 - PID Control Module65
- Algorithm 02 - On/Off Control Module78
- Algorithm 03 - Heating/Cooling PID Control Module (Dual€PID)86
- Algorithm 04 - Heating/ Cooling On/Off Control Module (Dual On/Off)98
- Numerical Calculation and Other Function Module Configurations107
- Algorithm 11 - Average107
- Algorithm 12 - Minimum Select109
- Algorithm 13 - Maximum Select111
- Algorithm 14 - Psychrometric Calculation ˚C113
- Algorithm 15 - Psychrometric Calculation ˚F116
- Algorithm 16 - Line Segment119
- Algorithm 17 - Input Selector121
- Algorithm 18 - Calculator123
- Algorithm 19 - Timer Functions125
- Algorithm 20 - Totalization129
- Algorithm 21 - Comparator133
56 more lines, from page 136 on
- Algorithm 22 - Sequencer136
- Algorithm 23 – Four Channel Line Segment (Version 1.1 or Later)152
- Algorithm 24 – Eight Channel Calculator (Version 1.1 or Later)154
- Time Program Functions156
- Time Schedule Configuration157
- Optimal Start/Stop Configuration161
- Programmable Logic Control Configuration174
- Dial-up Feature with an NDM188
- Trend Log (Versions 1.4, 2.3, 3.3, or Later)192
- Supervisory Mode Control Settings (General Module)195
- Controller Diagnostics204
- Power Up Conditions204
- Download/ Upload206
- Calibration Values209
- Appendix A: SX Tool Item Description and Tables211
- Appendix B: Item Structure217
- General Module Items Structure217
- Programmable Function Module Items Structure223
- Analog Input Module Items Structure226
- Analog Output Module Items Structure228
- Digital Output Module Items Structure229
- Extension Module Items Structure230
- Time Scheduling Items Structure236
- Optimal Start/Stop Items Structure237
- Network Information Module Items Structure238
- Network Digital Output Module Items Structure239
- Network Analog Output Module Items Structure241
- Network Digital Input Module Items Structure243
- Network Analog Input Module Items Structure244
- Appendix C: Programmable Function Module Items247
- Algorithm 1 - PID Controller247
- Algorithm 2 - On/Off Controller249
- Algorithm 3 - Heating/Cooling PID Controller251
- Algorithm 4 - Heating/Cooling On/Off Controller253
- Algorithm 11 - Average Calculation256
- Algorithm 12 - Minimum Selection257
- Algorithm 13 - Maximum Selection258
- Algorithm 14 - Psychrometric Calculation ˚C259
- Algorithm 15 - Psychrometric Calculation ˚F260
- Algorithm 16 - Line Segment Function261
- Algorithm 17 - Input Selector262
- Algorithm 18 - Calculator263
- Algorithm 19 - Timer Function264
- Algorithm 20 - Totalization266
- Algorithm 21 – Eight Channel Comparator269
- Algorithm 22 - Sequencer271
- Algorithm 23 – Four Channel Line Segment Function274
- Algorithm 24 – Eight Channel Calculator276
- Appendix D: Logic Variables279
- Appendix E: Analog Items and€Logic Variables for the Trend Log Module287
The whole text · 31 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 41-4
- DX-9100 Extended Digital Plant Controller5-10
- Software Configuration, pages 11 to 2011-20
- Software Configuration, pages 21 to 3021-30
- Software Configuration, pages 31 to 4031-40
- Software Configuration, pages 41 to 5041-50
- Software Configuration, pages 51 to 6051-60
- Software Configuration, pages 61 to 7061-70
- Software Configuration, pages 71 to 8071-80
- Software Configuration, pages 81 to 9081-90
- Software Configuration, pages 91 to 10091-100
- Software Configuration, pages 101 to 110101-110
- Software Configuration, pages 111 to 120111-120
- Software Configuration, pages 121 to 130121-130
- Software Configuration, pages 131 to 140131-140
- Software Configuration, pages 141 to 150141-150
- Software Configuration, pages 151 to 160151-160
- Software Configuration, pages 161 to 170161-170
- Software Configuration, pages 171 to 180171-180
- Software Configuration, pages 181 to 190181-190
- Software Configuration, pages 191 to 200191-200
- Software Configuration, pages 201 to 210201-210
- Appendix A: SX Tool Item Description and Tables211-216
- Appendix B: Item Structure, pages 217 to 226217-226
- Appendix B: Item Structure, pages 227 to 236227-236
- Appendix B: Item Structure, pages 237 to 246237-246
- Appendix C: Programmable Function Module Items, pages 247 to 254247-254
- Appendix C: Programmable Function Module Items, pages 255 to 262255-262
- Appendix C: Programmable Function Module Items, pages 263 to 270263-270
- Appendix C: Programmable Function Module Items, pages 271 to 278271-278
- Pages 279 to 288279-288
The file